Specifications

91
Data Parameters Transmission Parameters
LOW RANGE PROGRAM
Range: __________________________________________________________ ON/OFF
Used on the EGS system. This parameter indicates whether the low range program for the
transfer case is engaged or not. ON means that the program is engaged, and is adjusting the
transmission shift schedule. This program normally activates when the selector lever is placed in
the Neutral position while the engine runs in a stationary position.
LR VSS (1/MIN)
Range: ___________________________________________________ 0 to vehicle max
Used on the EGS system. This parameter displays the CAN signal from the traction system or
from the left rear wheel speed senor. The electronic transmission controller (ETC) samples this
value once per minute. The value should increase and decrease in proportion to the rotational
speed of the wheel.
MAP(%)
Range: _________________________________________________________ 0 to 100%
Used on EGS systems. No information is available at this time.
NOM. PRESS. TORQ. CONV. LOCK-UP(MBAR)
REG. PRESS. TORQ. CONV. LOCK-UP(MBAR)
Range: ______________________________________________________ not available
Used on the EAG system. These parameters display a variable current in millibars. Changing
operating conditions such as engine load and gear shifting determines when the torque
convertor locks up. No further information is available.
OIL CONDITION LONG TERM MONITOR
OIL CONDITION SHORT TERM MONITOR
Range: ______________________________________________________ not available
Used on the EGS system. These parameters display transmission oil condition. Transmissions
on EGS system vehicles use ATF certified for the life of vehicle. The manufacturer has no
scheduled recommended fluid changes. No further information is available at this time.
OPTIMAL CALC. MOD. PRESSURE(MBAR)
OPTIMAL CALC. SHIFT PRESSURE(MBAR)
Range: ______________________________________________________ not available
Used on the EGS system. These parameters display the desired modulating and shift pressure
as calculated by the electronic transmission control module (ETC). Modulating and shift pressure
values depend on vehicle operating conditions.
OUTPUT SHAFT SPEED (1/MIN)
Range: ___________________________________________________ 0 to vehicle max
Used on EAG and EGS systems. This parameter displays current output shaft speed. The
electronic transmission control module (ETC) samples output shaft speed once per minute.
PLANET. SPEED SENSOR (N2)(NOM.)
PLANET. SPEED SENSOR (N2)(CUR.)
PLANET. SPEED SENSOR (N3)(NOM.)
PLANET. SPEED SENSOR (N3)(CUR.)
Range: _____________________________________________________ –50 to 50 RPM
The data parameters above with “nominal” in their name indicate the calculated value for the
planetary gear speed stored in the electronic transmission control module (ETC). Those
parameters with “current” in their name indicate the current speed.
The Hall-effect planetary speed sensors, sometimes called RPM sensors, are mounted on the
valve bodies, and are permanently attached to the carrier via the contact tabs.