Specifications
67
Data Parameters Engine Parameters
O2 SENSOR, DOWNSTREAM CAT, CYL 1-3; 4-6; 7-9; 10-12
O2 SENSOR, DOWNSTREAM CAT
O2 SENSOR, DOWNSTREAM CAT, LEFT
O2 SENSOR, DOWNSTREAM CAT, RIGHT
O2 SENSOR, UPSTREAM CAT, CYL 1-3; 4-6; 7-9; 10-12
O2 SENSOR, UPSTREAM CAT
O2 SENSOR, UPSTREAM CAT, LEFT
O2 SENSOR, UPSTREAM CAT, RIGHT
Range: ________________________________________________________ 0 to 2.00 V
Used on ME27 and ME28 systems. The terms “1-3,” “4-6,” “7-9,” and “10-12” refer to four
separate groups of parameters. The oxygen sensor (O2S) is the primary sensor that indicates
whether the engine is running rich or lean. O2Ss have a range of 0.0 to 1.2 volts (V). A high 0.48
to 1.00 V signal indicates a rich mixture; a low signal indicates a lean mixture. Normally, the O2S
voltage ranges from 0.1 to 1.0 V. The O2S must be hot, and the ECU must be in closed loop
before the ECU will respond to the sensor signal. On some applications, individual cylinder sets
of O2S readings are useful for determining specific cylinder fuel mixture and misfire diagnosis.
O2S (LAMBDA) CONTROL
Range: ________________________________________________________ –10 to 10%
Used on DM, HFM and LH systems. This parameter is the short-term fuel metering correction
based on O2S input. Lambda control determines the injection time in order to maintain a
stoichiometric (14.7:1), or 1.0 Lambda, air-fuel ratio. Zero is the base setting, no correction.
Positive readings indicate increased injector duration to correct a lean condition, and negative
readings indicate reduced time to correct a rich condition.
O2S (LAMBDA) CONTROL APPROVED
Range: __________________________________________________________ YES/NO
Used on DM2 systems. This parameter shows whether the system is in closed loop, and if the
ECU is responding to oxygen sensor (O2S) feedback signals. The display reads YES in closed
loop and NO in open loop.
O2S (LAMBDA) CONTROL AFTER TWC
O2S (LAMBDA)CTRL AFT. TWC LEFT
O2S (LAMBDA)CTRL AFT.TWC RIGHT
Range: ______________________________________________________ not available
Used on ME10 and ME20 systems. These parameters are the outputs in milliseconds of lambda
control based on the downstream oxygen sensor (O2S) signals. No operation or range
information is available at this time.
O2S (LAMBDA) CONTROL BEFORE TWC
O2S (LAMBDA) CTRL BEF. TWC RIGHT
O2S (LAMBDA) CTRL BEFORE TWC LEFT
O2S CONTROL, UPSTREAM CAT(%)
Range: ________________________________________________________ –25 to 25%
Used on ME10 and ME20 and SIM4 systems. These parameters represent the short-term fuel
metering correction required to maintain a stoichiometric (14.7:1), or 1.0 Lambda, air-fuel ratio.
Fuel corrections are based on the indicated O2S signals. Zero is the base setting, no correction.
Positive readings indicate increased injector duration to correct a lean condition, and negative
readings indicate reduced on time to correct a rich condition.