User's Manual
OPERATION GUIDE.
OG_STD-502-R_v09e Circuit Design, Inc.
5
Electrical specification (Receiver)
Item Specification MIN TYP MAX Unit Remarks
Reception method Low IF
Maximum input level -13 dBm
Receiver sensitivity
(BER, 9.6 kbps)
-20 to + 65°C /all channels
-93 dBm error rate = < 1 %
Receiver sensitivity
(BER, 19.2 kbps)
-20 to + 65°C /all channels
-93 dBm error rate = < 1 %
Blocking EN300 440-1 compliant -45 dBm
2 signal test, 1% error
Spurious radiation
(1st Lo)
dBm
Power on -> County code reception 42 ms
Power on in the RX mode
Command reception -> RX 5 ms
Frequency change 3 ms
Command reception -> RX
start
TX to RX 2 ms
Terminal input -> Stable
operation
Actuation
time
Recovery from standby 1.2
Standby -> RX start