Specifications
OG_STD-302N-R_v15e Circuit Design, Inc.
4
OPERATION GUIDE
SPECIFICATIONS
STD-302N-R 434 MHz All ratings at 25 +/-10 °C unless otherwise noted
General characteristics
Item Units MIN TYP MAX Remarks
Applicable standard EN 300 220
Communication method Simplex, Half-duplex
Emission class F1D
Operating frequency range MHz 433.050 434.775
Operation temperature range °C -20 60 No dew condensation
Storage temperature range °C -30 75 No dew condensation
Aging rate ppm -1 1 TX freq., RX Lo freq.
Initial frequency tolerance ppm -1.5 1.5 TX freq., RX Lo freq.
Dimensions mm 30 x 50 x 9 mm Not including antenna
Weight g 25 g
Electrical specification <Common>
Item MIN TYP MAX Remarks
Oscillation type PLL controlled VCO
Frequency stability (-20 to 60°C) ppm -4 4 Reference frequency at 25 °C
TX/RX switching time ms 15 20 DI/DO
Channel step kHz 25
Data rate bps 2400 9600 DO/DI
Max. pulse width ms 15 DO/DI
Min. pulse width us 100 DO/DI
Data polarity Positive DO/DI
PLL reference frequency MHz 21.25 TCXO
PLL response ms 30 60 from PLL setting to LD out
Antenna impedance Ω 50 Nominal
Operating voltage V 3.0 5.5
TX consumption current mA 44 48 Vcc = 3.0 V
RX consumption current mA 26 30 Vcc = 3.0 V
Transmitter part
Item MIN TYP MAX Remarks
RF output power mW 10 Conducted 50 Ω
Deviation kHz 2.35 2.75 3.15 PN9 9600 bps
DI input level V 0 5.5 L= GND, H = 3 V- Vcc
Residual FM noise kHz 0.17 DI=L, LPF=20 kHz
-54
47-74, 87.5-118, 174-230, 470-862 MHz
-36 Other frequencies below 1000 MHz
Spurious emission dBm
-30 Frequencies above 1000 MHz
Adjacent CH power dBm -37 PN9 9600 bps CH25kHz/BW16kHz