STD-302S 429MHz operation guide

OG_STD-302S-429M_v11e Circuit Design, Inc.
16
OPERATION GUIDE
PLL FREQUENCY SETTING DATA REFERENCE
429 MHz ISM band (429.1750 – 429.7375 MHz)
No.
Channel
Frequency FCH
Expect
Frequency
EXPECT
Lock
Frequency
FVCO
Number of
Division n
Programable
Counter
N
Swallow Counter
A
(MHz) (MHz) (MHz)
1 429.1750 407.4750 407.4750 32598 509 22
2 429.1875 407.4875 407.4875 32599 509 23
3 429.2000 407.5000 407.5000 32600 509 24
4 429.2125 407.5125 407.5125 32601 509 25
5 429.2250 407.5250 407.5250 32602 509 26
6 429.2375 407.5375 407.5375 32603 509 27
7 429.2500 407.5500 407.5500 32604 509 28
8 429.2625 407.5625 407.5625 32605 509 29
9 429.2750 407.5750 407.5750 32606 509 30
10 429.2875 407.5875 407.5875 32607 509 31
11 429.3000 407.6000 407.6000 32608 509 32
12 429.3125 407.6125 407.6125 32609 509 33
13 429.3250 407.6250 407.6250 32610 509 34
14 429.3375 407.6375 407.6375 32611 509 35
15 429.3500 407.6500 407.6500 32612 509 36
16 429.3625 407.6625 407.6625 32613 509 37
17 429.3750 407.6750 407.6750 32614 509 38
18 429.3875 407.6875 407.6875 32615 509 39
19 429.4000 407.7000 407.7000 32616 509 40
20 429.4125 407.7125 407.7125 32617 509 41
21 429.4250 407.7250 407.7250 32618 509 42
22 429.4375 407.7375 407.7375 32619 509 43
23 429.4500 407.7500 407.7500 32620 509 44
24 429.4625 407.7625 407.7625 32621 509 45
25 429.4750 407.7750 407.7750 32622 509 46
26 429.4875 407.7875 407.7875 32623 509 47
27 429.5000 407.8000 407.8000 32624 509 48
28 429.5125 407.8125 407.8125 32625 509 49
29 429.5250 407.8250 407.8250 32626 509 50
30 429.5375 407.8375 407.8375 32627 509 51
31 429.5500 407.8500 407.8500 32628 509 52
32 429.5625 407.8625 407.8625 32629 509 53
33 429.5750 407.8750 407.8750 32630 509 54
Parameter name Value
Phase Comparing Frequency F
comp
[kHz] 12.5
Start Channel Frequency F
ch
[MHz] 429.1750
Channel Step Frequency [kHz] 12.5
Number of Channel 46
Prescaler M 64
Parameter name Value
Reference Frequency F
osc
[MHz] 21.25
Offset Frequency F
offset
[MHz] 21.7
: For data input
: Result of calculation
: Fixed value
Parameter name Value
Reference Counter R 1700
Programmable Counter N Min. Value 509
Programmable Counter N Max. Value 510
Swallow Counter A Min. Value 0
Swallow Counter A Max. Value 63