User's Manual

86 9500CE Terminal Reference Manual
Max / Min Length
Maximum Length
0~127 characters 127
Minimum Length
0~127 characters 0
Plessey
Supported on CCD / Laser Default
Enabled or Disabled Disabled
Convert to UK
Plessey
When enabled, each occurrence of the character “A”
will be converted to “X”.
OFF (Disabled)
Transmit Checksum
The checksum characters (2 digits) are included in the
data being transmitted.
ON (Enabled)
UPC-E
Supported on CCD / Laser Default
Enabled or Disabled Enabled
Convert to UPC-A
When enabled, the UPC-E reading will be expanded
into UPC-A. It will then be processed according to the
settings of UPC-A.
OFF (Disabled)
Transmit System
Number
When enabled, the system number will be included in
the data being transmitted.
OFF (Disabled)
Transmit Checksum
The checksum character is included in the data being
transmitted.
ON (Enabled)
Transmit Addon 2
When enabled, UPC-E Addon 2 can be decoded too. OFF (Disabled)
Transmit Addon 5
When enabled, UPC-E Addon 5 can be decoded too. OFF (Disabled)
EAN-8
Supported on CCD / Laser Default
Enabled or Disabled Enabled
Convert to EAN-13
When enabled, the EAN-8 reading will be expanded
into EAN-13. It will then be processed according to the
settings of EAN-13.
OFF (Disabled)
Transmit Checksum
The checksum character is included in the data being
transmitted.
ON (Enabled)
Transmit Addon 2
When enabled, EAN-8 Addon 2 can be decoded too. OFF (Disabled)
Transmit Addon 5
When enabled, EAN-8 Addon 5 can be decoded too. OFF (Disabled)
EAN-13
Supported on CCD / Laser Default
Enabled or Disabled Enabled
Convert to ISBN
When enabled, the EAN-13 reading that starts with 978 OFF (Disabled)