User's Manual
  Chapter 5    105 
 Buffer All Symbols / Transmit Macro PDF When 
Complete 
(to transmit all decoded data from an entire Macro 
PDF sequence only when the entire sequence is 
scanned and decoded; if the decoded data exceeds 
the limit of 50 symbols, no transmission because 
the entire sequence was not scanned!) 
 Transmit Any Symbol in Set / No Particular Order 
(to transmit data from each Macro PDF symbol as 
decoded, regardless of the sequence; when 
selecting this mode, enable Transmit Control 
Header below!) 
 Passthrough All Symbols 
(to transmit and decode all Macro PDF symbols 
and perform no processing; in this mode, the host 
is responsible for detecting and parsing the Macro 
PDF sequences) 
Transmit Control 
Header 
When enabled, it activates transmission of the control 
header, which contains the segment index and the file 
ID.
For example, the field may be \92800000\725\120\343. 
The five digits after the \928 are the segment index (or 
block index), and \725\120\343 is the file ID. 
 Enable this when selecting “Transmit Any Symbol 
in Set / No Particular Order” above. 
 Disable this when selecting “Buffer All Symbols / 
Transmit Macro PDF When Complete”. 
 This has no effect when selecting “Passthrough All 
Symbols”. 
NO (Disabled) 
Escape Characters 
When enabled, it uses the backslash “\” as an Escape 
character for systems that can process transmissions 
containing special data sequences. 
 None 
 GLI Protocol 
(to format special data according to the Global 
Label Identifier protocol; this only affects the data 
portion of a Macro PDF symbol transmission; the 
Control Header, if enabled, is always sent with 
GLI formatting) 
None (Disabled) 