User's Manual
86  9500CE Reference Manual 
  Max / Min Length 
Maximum Length 
0~127 characters  127 
Minimum Length 
0~127 characters  0 
Plessey  Supported on CCD / Laser  Default 
Enabled or Disabled  Disabled 
Convert to UK 
Plessey 
When enabled, each occurrence of the character “A” 
will be converted to “X”. 
OFF (Disabled) 
Transmit Checksum 
The checksum characters (2 digits) are included in the 
data being transmitted. 
ON (Enabled) 
UPC-E  Supported on CCD / Laser  Default 
Enabled or Disabled  Enabled 
Convert to UPC-A 
When enabled, the UPC-E reading will be expanded 
into UPC-A. It will then be processed according to the 
settings of UPC-A. 
OFF (Disabled) 
Transmit System 
Number 
When enabled, the system number will be included in 
the data being transmitted. 
OFF (Disabled) 
Transmit Checksum 
The checksum character is included in the data being 
transmitted. 
ON (Enabled) 
Transmit Addon 2 
When enabled, UPC-E Addon 2 can be decoded too.  OFF (Disabled) 
Transmit Addon 5 
When enabled, UPC-E Addon 5 can be decoded too.  OFF (Disabled) 
EAN-8  Supported on CCD / Laser  Default 
Enabled or Disabled  Enabled 
Convert to EAN-13 
When enabled, the EAN-8 reading will be expanded 
into EAN-13. It will then be processed according to the 
settings of EAN-13. 
OFF (Disabled) 
Transmit Checksum 
The checksum character is included in the data being 
transmitted. 
ON (Enabled) 
Transmit Addon 2 
When enabled, EAN-8 Addon 2 can be decoded too.  OFF (Disabled) 
Transmit Addon 5 
When enabled, EAN-8 Addon 5 can be decoded too.  OFF (Disabled) 
EAN-13  Supported on CCD / Laser  Default 
Enabled or Disabled  Enabled 
Convert to ISBN 
When enabled, the EAN-13 reading that starts with 978  OFF (Disabled) 