User's Manual
  Chapter 5 錯誤! 尚未定義樣式。 93 
  Length within Range 
For example, if “Length within Range” is selected, the 
terminal will only accepts those barcodes with lengths 
that fall between the maximum and minimum lengths; 
otherwise, data will be rejected. 
*If “Code 39 Full ASCII” is enabled, “Length within 
Range” or “Any Length” is the preferred option. 
Verify Check Digit 
When enabled, the checksum verification will be 
performed in decoding. 
If the checksum is incorrect, data will be rejected. 
*Only barcodes that include a Modulo 43 check digit 
are decoded. Enable this feature if the barcode contains 
a Modulo 43 check digit. 
NO (Disabled) 
Transmit Check Digit 
When enabled, the check digit will be included in the 
data being transmitted. 
*By default, this feature (Not Transmit Check Digit) 
only works when “Verify Check Digit” is enabled first! 
NO (Disabled) 
Code 39 Full ASCII 
When enabled, Code 39 Full ASCII will be supported 
instead. All the alphanumeric and special characters are 
included. 
NO (Disabled) 
Code 93  Supported on (Extra) Long Range Laser  Default 
Enable Code 93 
YES or NO  NO (Disabled) 
Select Discrete 
Length 
Refer to Code 39 above.  Any Length 
Interleaved 25  Supported on (Extra) Long Range Laser  Default 
Enable Interleaved 
25 
YES or NO  YES (Enabled) 
Select Discrete 
Length 
The length of a barcode refers to the number of 
characters (i.e. human readable characters), including 
check digit(s) it contains. 
The weak structure of some barcodes may cause a 
“short scan” error. To prevent this, select specific 
lengths: one or two discrete lengths 
  Any Length 
  One Discrete Length 
  Two Discrete Lengths 
  Length within Range 
For example, if “Length within Range” is selected, the 
Any Length 