User's Manual

30
9300 Mobile Compute
r
Reference Manual
Auto Power Off Mode Press the scan trigger to start with scanning.
The scanning won't stop until the preset timeout expires, and, the
preset timeout period re-counts after each successful decoding.
Read Redundancy None
None No redundancy means one successful decoding will make the reading valid
and induce the "READER Event".
One time, Two times,
or Three times
The higher the reading security is (that is, the more redundancy the user
selects), the slower the reading speed gets.
If "Three Times" is selected, it will take a total of four consecutive
successful decodings of the same barcode to make the reading valid.
SYMBOLOGY SETTINGS TABLE
CCD/Laser Description Default
Codabar Enable
Select Start/Stop
Characters
If "Transmit Start/Stop Characters" is desired, select one
set:
abcd / abcd
abcd / tn*e
ABCD / ABCD
ABCD / TN*E
abcd / abcd
Transmit Start/Stop
Characters
Decide whether to include the start
/
stop characters in the
data being transmitted.
No
Code 128 Enable
EAN-128 Enable
Transmit Code ID
Decide whether to include Code ID (“]C1”) will be included
in the data being transmitted.
No
Industrial 25 (= Discrete 25) Enable
Start/Stop Selection This decides the readability of all 2 of 5 symbology
variants. For example, flight tickets actually use an
Industrial 2 of 5 barcode but with Interleaved 2 of 5
start/stop pattern. In order to read this barcode, the
start/stop pattern selection parameter of
Industrial 2 of 5
should set to "Interleaved 25".
Industrial 25
Verify Checksum Decide whether to verify the checksum. If the checksum is
incorrect, the barcode will not be accepted.
No
Transmit Checksum Decide whether to include the checksum in the data being
transmitted.
Yes
Select Length
One or two fixed lengths
Range
4~127
Interleaved 25 Enable
Start/Stop Selection Refer to Industrial 25. Interleaved
25