User Manual

6
3.3 RF Bases
The connection from the host computer to the base is RS-232, while the connection between bases is
RS-485. Up to 16 bases can be connected together in one RF system. If two or more bases are
connected together, the one connected to the host computer should be set to master mode, and the
others in slave mode.
433 MHz Base Properties (3510)
Mode: 1-standalone, 2-slave, 3-master
Channel: 1 ~ 4
ID: 01 ~ 16
Group: 1 ~ 3
Time out: 1 ~ 99 seconds, duration of retries for sending data
Output power: 1~5 levels (10, 5, 4, 0, -5dBm)
Baud rate: 115200, 57600, 38400, 19200, 9600
2.4 GHz Base Properties (3550)
Mode: 1-standalone, 2-slave, 3-master
Channel: 1 ~ 6
ID: 01 ~ 16
Group: 1
Time out: 1 ~ 99 seconds, duration of retries for sending data
Output power: maximum 64mW
Baud rate: 115200, 57600, 38400, 19200, 9600