User's Manual

Table Of Contents
Chapter 6 Applying Formats for Data Editing
2. Read the Decimal Valuebarcode on page 263 for the desired field length.
3. Read the “Validate” barcode on the same page to complete this setting.
Additional Fields
Up to five additional fields can be created for each editing format; each of them is numbered from AF1
to AF5 accordingly.
If “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status
will then become applicable. You may decide whether or not to apply Key Status when “Normal
Key” is selected for Key Type.
Key Type Key Status
Scan Code Up to 2 scan code values are allowed. N/A
Normal Key
Up to 4 character strings are allowed.
Add Shift
Add Left Ctrl
Add Left Alt
Add Right Ctrl
Add Right Alt
Refer to Keyboard Wedge Table.
1. Read the barcode below to specify an additional field, one at a time.
Additional Field 1…
Additional Field 2…
Additional Field 3…
Additional Field 4…
Additional Field 5…
233
Update