User's Manual

Table Of Contents
44
1800 Series Handheld RFID Reader Reference Manual
1.6 VIBRATOR
The RFID Reader has a built-in vibrator, which can be issued command for feedback. This
can be helpful when working in noisy environments.
For good read/write, the vibrator will vibrate for 1 second then stop. The vibration and
duration are programmable.
STATUS
RFID Reader supports a vibration option that you can enable/disable by issuing “#@sys_viben=”
command.
Command:
#@sys_viben?\r
Purpose Get Vibrator Status
Response OK,[m]\r (Default m= ‘0’)
[m]: ‘0’ – Disable
‘1’ Enable
ERR,[code]\r
#@sys_viben=[m]\r
Purpose Set Vibrator Status
Response OK\r
ERR,[code]\r
DURATION
By default, a good read vibration stays on for 1 second. Specify a value, ranging from 1 to 254 in
units of 100 milliseconds.
Command:
#@sys_vibdu?\r
Purpose Get Vibrator Duration
Response OK,[m]\r (Default m= ‘10’)
[m]: Duration=‘1’ ~ ‘254’
ERR,[code]\r