User's Manual

Table Of Contents
30
1800 Series Handheld RFID Reader Reference Manual
Example:
Command
#@sys_memsize? get current memory size
Response (s)
OK, 4072
Command
#@sys_memen=1 enter memory mode
Response (s)
OK
Command
#@sys_memdly=4 set the delay time of data transmission to 2 sec.
Response (s)
OK
Command
#@sys_memup upload memory data
Response (s)
1. 2012-04-18 30003430333130303132303030304221
2. 2012-04-18 30003430333130303132303030304221
3. 2012-04-18 30003430333130303132303030304221
OK
Command
#@sys_memclr clear memory size
Response (s)
OK
] 2sec.
] 2sec.