Appendix I Firmware Upgrade
USE BLUETOOTH
®
DONGLE
Please refer to 3.1.3 Bluetooth® HID and SPP Slave for the connection with Bluetooth
®
dongle, and go through steps 3 (run “#@sys_dlfw=0” or “#@sys_dlfw=1” command) to
6 described in the Use USB Virtual COM section.
USE 3610
Please refer to 3.2 Connecting via 3610 for connecting to 3610, and go through steps 3
(run “#@sys_dlfw=0” or “#@sys_dlfw=1” command) to 6 described in the Use USB
Virtual COM section.
Note: Please upgrade firmware to one RFID reader at a time, while using Bluetooth
®
connection. For example, turn off each of the rest RFID readers when there is
more than one RFID reader connected to host computer.
USE <F2>+<TRIGGER>
1) Power Off RFID Reader.
2) Press and hold the <F2>+<Trigger> for 3 seconds to enter Firmware Upgrade mode.
3) Use USB cable to connect RFID Reader and host computer.
4) Run the download utility “ProgLoad.exe” on host computer to upgrade the firmware.
Note: <F2>+<Trigger> firmware upgrade only supports Windows CDC Virtual COM
driver. Please refer to 2.1 USB Interface to configure USB type.