Chapter 5
DefinING Output Format
5.4 OUTPUT EPC DATA VIA USB VIRTUAL COM
Users can decide whether to output data via the USB Virtual COM port. Once the ‘m’
parameter of this command is set to ‘1’, the EPC data originally transmitted by
Bluetooth
®
communications will be output by the USB Virtual COM port. Thus, Bluetooth
®
communications stop outputting the EPC data.
Command:
#@dat_2usb?\r
Purpose Get the Setting Value
Response OK,[m]\r
[m]: Output EPC Data via USB Virtual COM
‘0’ Disable (default)
‘1’ Enable outputting EPC Data via USB Virtual COM
ERR,[code]\r
#@dat_2usb=[m]\r
Purpose Specify the Setting
Response OK\r