User's Manual

Table Of Contents
138
1800 Series Handheld RFID Reader Reference Manual
Default is inventory
Response (s)
OK,0
18. 2012-04-12 Fri 04:00 55.95 30003430333130303132303030304221
Command
#@dat_rfseq?
get the sequence of RFID Data
Default sequence is PC, EPC and then CRC
Response (s)
OK,2,3,1,4,0
19. 2012-04-12 Fri 04:00 55.95 3000 343033313030313230303030 4221
PC + EPC + CRC
Command
#@dat_rfseq=3,0,0,0,0 only show EPC
Response (s)
OK
20. 2012-04-12 Fri 04:00 55.95 343033313030313230303030
EPC
UHF Data Separators
The separator to be configured or retrieved can present in ASCII characters or
hexadecimal numbers. Refer to
ASCII Table.
Command:
#@dat_rfsprh?\r, #@dat_rfspr?\r
Purpose Get the Separators of Each field in EPC Tag Data Section
Request #@dat_rfsprh?\r Response data will be shown in Hexadecimal value
#@dat_rfspr?\r Response data will be shown in character
Response OK,[m],[n],[o],[p]\r
[m]: separator follows field1. Default= ‘00’ (NULL)
[n]: separator follows field2. Default= ‘00’ (NULL)
[o]: separator follows field3 . Default= ‘00’ (NULL)
[p]: separator follows field4 . Default= ‘00’ (NULL)
ERR,[code]\r
#@dat_rfspr=[m],[n],[o],[p],[q]\r