User's Manual
Table Of Contents
- IMPORTANT NOTICES
- RELEASE NOTES
- INTRODUCTION
- QUICK START
- UNDERSTANDING RFID READER
- COMMUNICATION INTERFACE
- SETTING UP A WPAN CONNECTION
- SCANNING UHF RFID TAG
- DEFINING OUTPUT FORMAT
- ALTERNATE MODE
- SPECIFICATIONS
- FIRMWARE UPGRADE
- ASCII TABLE
- SCAN CODE
- STATUS CODE
128
1800 Series Handheld RFID Reader Reference Manual
5.2.1 DATA COUNTER SECTION
Define a serial number to output data. The serial number would be specified in 6 digits
beginning from 000001. When the counter is up to 999999, it will be reset to 000001.
Default Format:
Reset Counter Event
There are three events supported to reset the counter. With the parameter set to ‘1’, the
counter will be reset when the event occurs.
Command:
#@dat_rstcnt?\r
Purpose Get the Setting of Reset Counter Event
Response
OK,[m],[n],[o]\r (Default m= ‘1’, n= ‘0’, o= ‘1’)
Reset Event Enable
Disable
[m] Reset Counter command accepted ‘1’ ‘0’
[n] UHF Power On ‘1’ ‘0’
[o] new Bluetooth
®
connection established ‘1’ ‘0’
ERR,[code]\r
#@dat_rstcnt=[m],[n.],[o]\r
Purpose Enable/Disable Counter Reset Event
Response OK\r
ERR,[code]\r
#@dat_rstcnt\r
Purpose Reset Data Counter
Response OK\r
ERR,[code]\r
Note: Besides the configurable events above, Data Counter will also be reset when
system powers up.