User's Manual
Table Of Contents
- IMPORTANT NOTICES
- RELEASE NOTES
- INTRODUCTION
- QUICK START
- UNDERSTANDING RFID READER
- COMMUNICATION INTERFACE
- SETTING UP A WPAN CONNECTION
- SCANNING UHF RFID TAG
- DEFINING OUTPUT FORMAT
- ALTERNATE MODE
- SPECIFICATIONS
- FIRMWARE UPGRADE
- ASCII TABLE
- SCAN CODE
- STATUS CODE
96
1800 Series Handheld RFID Reader Reference Manual
4.2 SCAN TIME
4.2.1 TIMEOUT
You have to specify the scanning timeout interval (0~254 sec.; 0= Disable) when the
scan mode is set to Single Mode.
Operation will stop if the operation time = Scan Session Timeout and No Tag data is
received.
The range of timeout is 0~254 second. By default the value is set to ‘0’ to disable
scanning timeout.
Command:
#@rf_tscan?\r
Purpose Get Scan Session Timeout
Response OK,[m]\r (Default m= ‘0’)
[m]: Timeout, ‘0’ ~ ‘254’
ERR,[code]\r
#@rf_tscan=[m]\r
Purpose Set Scan Section Timeout
Response OK\r
ERR,[code]\r
Note: This command is available for Single Mode. For example, if you set the
“#@rf_tscan” value to 5, the waiting time is set to 5 sec. upon pressing the trigger.
If no tag is scanned within that period, the operation will stop.