User's Manual
    73 
  Chapter 3
  Set Up a WPAN Connection
3.1.2 CONFIGURE RELATED SETTINGS 
BROADCASTING 
RFID Reader can be configured to hide itself from other devices equipped with Bluetooth
®
 wireless 
technology. Simply disable the device name broadcasting setting so that it won’t be discovered by any 
other computer. However, broadcasting must be enabled for establishing an initial connection with 
RFID Reader. For example, disable device name broadcasting after successfully connecting RFID 
Reader to one WorkStation. Such connection will be maintained automatically unless RFID Reader is 
removed from the paired device list (called unpairing) by the WorkStation or any changes made to 
authentication and the PIN code. If you want another WorkStation to connect to RFID Reader, you 
have to enable device name broadcasting firstly.   
Command: 
#@bt_visible?\r 
Purpose Get Bluetooth
®
 Parameter 
Response  OK,[m]\r (Default m= ‘1’) 
[m]: Discoverable 
 ‘0’ – Disable 
 ‘1’ – Enable 
ERR,[code]\r 
#@bt_visible=[m]\r 
Purpose Set Bluetooth
®
 Parameter 
Response OK\r 
ERR,[code]\r 
Note: By default, device name broadcasting is enabled (which is required for initial 
connection). 
AUTHENTICATION 
When the authentication and PIN code are changed on the RFID Reader, you have to remove the RFID 
Reader from the paired device list (called unpairing) and go through the whole process to re-establish 
the connection.   