User's Manual

68
1800 Series Handheld RFID Reader Reference Manual
2.6.4 INTER-FUNCTION DELAY
By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in
units of milliseconds, to match the computer response time of the keyboard interface. Such
delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The
longer the delay time is, the slower the transmission speed will be.
Options Parameter Description
‘0’ (Default) ‘0’~‘254’ The range is from 0 to 254 in units of millisecond.
2.6.5 HID CHARACTER TRANSMIT MODE
By default, HID interface sends data to the host in batch. You may configure the RFID
Reader to “By Character” to process data one character at a time.
Options Parameter Description
Batch Processing
(Default)
‘0’ Process data by Batch.
By Character ‘1’ Process data by Character
Note: “By Character” transmit mode is required when working with iPhone or iPad.