User's Manual
58
1800 Series Handheld RFID Reader Reference Manual
2.5 BLUETOOTH
®
SPP MASTER
As a SPP master device, RFID Reader will be able to resume connection with the host
computer upon powering on again, as long as the host application is running. If RFID Reader
fails to resume connection, it will try every 5 seconds to re-connect to the host computer
unless you issue the “#@bt_reset” or “#@sys_ldstbl=” command.
For Bluetooth
®
SPP Master Connection, refer to 3.1.4 Bluetooth® SPP Master.
Note: In SPP Master Mode, RFID Reader has to connect within the specified period of time (2
minutes by default). During the connection, the RFID Reader will enter to Power
Saving Mode to save power. It will automatically power off when the time is up. Refer
to 1.1 Power
.
2.5.1 ACTIVATE BLUETOOTH
®
SPP MASTER MODE
Configure the output interface to SPP Master by issuing the “bt_type=” and to parameter ‘3’.
How to connect with the target machine?
There are two parameters for “#@bt_target=” command to SPP Master target machine. One is
Bluetooth
®
targe – SPP Master and another is the symbolical No. of target machine.
Command:
#@bt_target?\r
Purpose Get Bluetooth
®
Target Machine
Response OK,[m],[n]\r
[m]: Bluetooth
®
Type, ‘0’ – SPP Master, ‘1’ – 3610
[n]: MACID of target Machine or S/N of 3610
ERR,[code]\r
#@bt_target=[m],[n]\r
Purpose Set Bluetooth
®
Target Machine
Response OK
ERR,[code]
Exit SPP Master Mode
To stop such re-connection, you can issue the “#@bt_reset” or “#@sys_ldstbl=” command so that
the current connection record (= MACID) will be cleared. Then, the RFID Reader will restart itself
automatically. Go through the whole process in Set Up a WPAN Connection
to establish a new WPAN
connection.