DEFAULT SETTINGS 
SAVE USER SETTINGS AS DEFAULTS 
For the RFID Reader to keep the customized settings as user defaults, you must issue 
“#@sys_svusrtbl” command.  
Note:  After issuing the command, the current settings will be saved as user defaults. 
Command: 
#@sys_svusrtbl\r 
Purpose  Save User Defined Setting 
Response OK\r 
ERR,[code]\r 
RESTORE USER/FACTORY DEFAULTS 
For the RFID Reader to restore the User Defaults, which you have saved earlier, you must 
issue “#@sys_ldstbl=1” command. Alternatively, you can also issue “#@sys_ldstbl=0” 
command to restore Factory Default. 
Command: 
#@sys_ldstbl=[m]\r 
Purpose Load Default Setting 
Request #@sys_ldstbl=[m]\r 
[m]: ‘0’ – Factory Default 
 ‘1’ – User Default 
Response OK\r 
ERR,[code]\r 