User's Manual
136
1800 Series Handheld RFID Reader Reference Manual
5.5.2 READ/WRITE TAG
By default, the RFID Reader access mode is set to Inventory to get EPC of a tag. If you want
to read all data stored in a tag, you would issue “#@rf_func=1” command that allows you
to read reserved, EPC, TID or User bank.
RFID Function
Command:
#@rf_func?\r
Purpose Get RFID Function
Response OK,[m]\r (Default m= ‘0’)
[m]: RFID Function
‘0’ – Inventory
‘1’ – Read Tag Memory
‘2’ – Write Tag Memory
ERR,[code]\r
#@rf_func=[m]\r
Purpose Set RFID Function
Response OK\r
ERR,[code]\r