User's Manual
128
1800 Series Handheld RFID Reader Reference Manual
ERR,[code]\r
Pattern
Define the hexadecimal pattern that is used to be compared.
Command:
#@rf_xepcpt?\r
Purpose Get Excluded EPC Pattern
Response OK,[m]\r (Default m= ‘00’)
[m]: EPC pattern in hexadecimal value
ERR,[code]\r
#@rf_xepcpt=[m]\r
Purpose Set Excluded EPC Pattern
Response OK\r
ERR,[code]\r
#@rf_xepcpt2?\r
Purpose Get Excluded EPC2 Pattern
Response OK,[m]\r (Default m= ‘00’)
[m]: EPC pattern in hexadecimal value.
ERR,[code]\r
#@rf_xepcpt2=[m]\r
Purpose Set Excluded EPC2 Pattern
Response OK\r
ERR,[code]\r
State
Disable or Enable Excluded EPC Filter function.
Command:
#@rf_xepcen?\r
Purpose Get Excluded EPC State
Response OK,[m]\r (Default m= ‘0’)
[m]: ‘0’ – disable, ‘1’ – enable, ‘2’ – enable range filter
ERR,[code]\r
#@rf_xepcen=[m]\r
Purpose Set Excluded EPC State
Response OK\r