User's Manual
113
Chapter 4
Define Output Format
4.5 SECTION SEQUENCE
After finishing all section configurations, you can adjust the sequence or disable the section.
Command:
#@dat_seq?\r
Purpose Get the Setting of Output Data Sequence
Response
OK,[m],[n],[o]\r (Default m= ‘1’, n= ‘2’, o= ‘3’)
[m]: Section in sequence 1
[n]: Section in sequence 2
[o]: Section in sequence 3
Data section will be one of the following:
[m]/[n]/[o] Section
‘0’
Disable this section
‘1’
Count section
‘2’
Time Stamp section
‘3’
RFID Data section
ERR,[code]\r
#@dat_seq=[m],[n],[o]\r
Purpose Set Output Data Sequence