User's Manual

96
1800 Series Handheld RFID Reader Reference Manual
4.1 LETTER CASE (HID MODE ONLY)
By default, the alphabetic transmission is case-sensitive, meaning that the alphabet will be
transmitted according to their original case. Ignoring the original letter case, select [Upper
Case] to output data in upper case only; otherwise, select [Lower Case] to output data in
lower case only. Refer to 2.3.1 Activate Bluetooth® HID & Select Keyboard Type or 2.6.1
Activate USB HID & Select Keyboard Type.
4.2 OUTPUT FORMAT
You have to define the output data format firstly before capturing the data transmission
from RFID Reader. There are three output formats specified to various Bluetooth
®
interface.
BT SPP/USB VCOM via 3610
The output formats for Bluetooth
®
SPP/USB VCOM via 3610 are specified to Packet Data,
Hexadecimal and Raw Data. The default value is Packet Data.
BT HID/USB HID via 3610
The output formats for Bluetooth
®
HID/USB HID via 3610 are specified to Hexadecimal and
Raw Data. The default value is Hexadecimal.
Note: Bluetooth
®
HID or USB HID via 3610 interface does not support Packet Data as an
output format.
Command:
#@dat_fmt?\r
Purpose Get Current Output Data Format
Response
OK,[m]\r (Default m=
‘0’)
[m]:
Output Data Format
[m] BT SPP / USB VCOM via 3610 BT HID / USB HID via 3610
‘0’
Packet Data Hexadecimal
‘1’
Hexadecimal
‘2’
Raw Data Raw Data
ERR,[code]\r
#@dat_fmt=[m]\r
Purpose Set New Output Data Format
Response OK\r
ERR,[code]\r
Example:
Packet Data: