Specifications
    61 
Update 
  Chapter 2
 Selecting Output Interface
2.1.4 INTER-FUNCTION DELAY 
By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254, 
to match the computer response time of the keyboard interface. Such delay time is 
inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the 
delay time is, the slower the transmission speed will be. 
Value 
Delay Time  Value  Delay Time 
0  Disable  195 ~ 204  200 millisecond 
1 ~ 14  10 millisecond  205 ~ 214  210 millisecond 
15 ~ 24  20 millisecond  215 ~ 224  220 millisecond 
25 ~ 34  30 millisecond  225 ~ 234  230 millisecond 
35 ~ 44  40 millisecond  235 ~ 244  240 millisecond 
45 ~ 54  50 millisecond  245 ~ 254  250 millisecond 
… …     
Inter-Function 
Delay… (*0~254) 
1)  Read the barcode to specify the inter-function delay.      
2)  Read the “
Decimal Value” barcode on page 217 for the desired inter-function delay 
(millisecond). 
3)  Read the “Validate” barcode on the same page to complete this setting. 
2.1.5 HID CHARACTER TRANSMIT MODE 
By default, HID interface sends data to the host in batch. You may have the scanner read 
the “By Character” barcode to process data one character at a time. 
*Batch Processing 
By Character 
Note:  “By Character” transmit mode is required when working with iPhone or iPad. 