Specifications
    101 
Update 
  Chapter 5
 Defining Output Format
5.4 CODE ID 
Up to two characters for Code ID can be configured for each symbology. To make the 
Code ID configuration easier, the scanner provides five pre-defined Code ID sets that you 
can select one and make necessary changes on it. 
  If "Bluetooth HID" is configured for interface, Key Type and Key Status will then 
become applicable. You may decide whether or not to apply Key Status when “Normal 
Key” is selected for Key Type. Refer to 
Keyboard Wedge Table. 
Key Type 
Key Status 
Scan Code   Up to 1 scan code values are allowed.  N/A 
Normal Key  Up to 2 character strings are allowed. 
  Default setting 
  Add Shift 
  Add Left Ctrl 
  Add Left Alt 
  Add Right Ctrl 
  Add Right Alt 
  Add Break 
For example, read labels for [Add Shift] and 
the character [A]. 
Note: "]C1" is the Code ID of EAN-128 barcodes; "]e0" is the default Code ID of RSS 
barcodes. 
5.4.1 SELECT PRE-DEFINED CODE ID 
Code ID options  Set 1  Set 2  Set 3  Set 4  Set 5 
Code 39  A  C  Y  M  A 
Italian Pharmacode  A  C  Y  M  A 
French Pharmacode  A  C  Y  M  A 
Industrial 25 C H H H S 
Interleaved 25  D  I  Z  I  S 
Matrix 25 E G G G S 
Codabar F  N  X  N  F 
Code 93 I L L L G 
Code 128 H K K K C 
UPC-E S E C E E 
EAN-8 P B B FF E 
EAN-13 M A A F E 