User Manual
Table Of Contents
- Important Notices
- Release Notes
- Introduction
- Quick Start
- Understanding the Barcode Scanner
- 1.1 Battery
- 1.2 Memory
- 1.3 LED Indicator
- 1.4 Beeper
- 1.5 Send “NR” to Host
- 1.6 Scan Modes
- 1.7 Scanning Timeout
- 1.8 Delay between Re-read
- 1.9 Read Redundancy (1D)
- 1.10 Addon Security for UPC/EAN Barcodes
- 1.11 Effective Decoding Area
- 1.12 Negative Barcodes
- 1.13 Operation Mode
- 1.14 Imager Preferences
- 1.15 Signature Capture
- Selecting Output Interface
- Setting up a WPAN Connection
- Specifications
94
Enter Setup
1564 Barcode Scanner User Guide
2.5 RS-232 VIA 3656
Use the RS-232 cable to connect the scanner via 3656 to the serial port of PC, and
connect the power supply cord. The associated RS-232 parameters must match those
configured on the computer. You may run HyperTerminal.exe on your computer, and the
scanned data will be transmitted to the computer.
RS-232 Settings Defaults
Baud Rate, Data Bit, Parity, Stop Bit 115200 bps, 8 bits, No parity, 1 stop bit
Flow Control None
Inter-Character Delay 0 (ms)
Inter-Function Delay 0 (ms)
ACK/NAK Timeout 0
ACK/NAK Beep Disable
2.5.1 ACTIVATE RS-232 INTERFACE
Activate 3656
RS-232 Interface
2.5.2 BAUD RATE
*115200 bps
57600 bps
38400 bps
19200 bps
9600 bps