User Manual
Table Of Contents
- IMPORTANT NOTICES
- RELEASE NOTES
- INTRODUCTION
- QUICK START
- UNDERSTANDING THE BARCODE SCANNER
- SELECTING OUTPUT INTERFACE
- SETTING UP A WPAN CONNECTION
- CHANGING SYMBOLOGY SETTINGS
- 4.1 CODABAR
- 4.2 CODE 25 – INDUSTRIAL 25
- 4.3 CODE 25 – INTERLEAVED 25
- 4.4 CODE 25 – MATRIX 25
- 4.5 CODE 39
- 4.6 CODE 93
- 4.7 CODE 128
- 4.8 EAN-8
- 4.9 EAN-13
- 4.10 GS1-128 (EAN-128)
- 4.11 ISBT 128
- 4.12 MSI
- 4.13 FRENCH PHARMACODE
- 4.14 ITALIAN PHARMACODE
- 4.15 PLESSEY
- 4.16 GS1 DATABAR (RSS FAMILY)
- 4.17 TELEPEN
- 4.18 UPC-A
- 4.19 UPC-E
- DEFINING OUTPUT FORMAT
- APPLYING FORMATS FOR DATA EDITING
- SPECIFICATIONS
- Appendix I - FIRMWARE UPGRADE
- Appendix II - HOST SERIAL COMMANDS
- Appendix III - KEYBOARD WEDGE TABLE
- Appendix IV - NUMERAL SYSTEMS
167
Update
Chapter 6
Applying Formats for Data Editin
g
6.3.2 EXAMPLE II
Extract the date code, item number, and quantity information from barcodes.
Data in a barcode is encoded like this:
From the 1
st
character to the 6
th
character is the date code.
From the 7
th
character to the dash ‘-’ character is the item number.
After the dash ‘-’ character is the quantity information.
Data will be transmitted like this:
The item number goes first, then a TAB character, followed by the date code, then another
TAB character, and finally the quantity information.
The editing format should be configured as follows:
1. Read the “Enter Setup” label to enter the Configuration Mode.
2. Read the “Configure Format 2” label.
3. Read the “Three Fields” label.
4. Read the “Divide Field 1 by Length” label, and set length to 6.
Field 1 data starts from the 1
st
character to the 6
th
character.
5. Read the “Select Field Separator to Divide Field 2” label, and use a dash ‘-’ character.
Field 2 data starts from the 7
th
character until the dash ‘-’ character is met.
6. Read the “Additional Field 1” label, and use a tab character for the field.
7. Read the “Start (Programming)” label to program the transmission sequence.
8. Read the “Field 2”, “Additional Field 1”, “Field 1”, “Additional Field 1”, “Field 3” labels.
9. Read the “End” label to complete the transmission sequence (F2 A1 F1 A1 F3) setting.
10. Read the “End Programming Format” label to complete the setting of Editing Format 1.
11. Read the “Enable Format 2” label to apply Editing Format 2 to all code types.
12. Read the “Update” label to exit the Configuration Mode.