User's Manual
Table Of Contents
6.7 UPCA 
•  Checksum Transmission: If this parameter is enabled, the checksum 
characters (two characters) will be transmitted together with data. 
•  Convert to EAN13: If this parameter is enabled, the UPCA read will be 
expanded into EAN13, and the following processing will follow the 
parameters configured for EAN13. 
6.11 Telepen 
•  Telepen Output: There are two flavors of encoding formats for Telepen. 
One is the original Telepen format, the other is AIM Telepen format. User 
can choose the desired encoding format for Telepen readings. 
•  System Number Transmission: If this parameter is enabled, the system 
number will be included in the data being transmitted. 
•  Checksum Transmission: If this parameter is enabled, the checksum 
character will be included in the data being transmitted. 
6.12 RSS 
•  Code ID Selection: User has choice of using RSS Code ID (‘]e0’) or 
EAN128 Code ID (‘]C1’). 
6.8 EAN13 
•  ISBN / ISSN Conversion: If these parameters are enabled, the scanner will 
convert the code read into ISBN or ISSN code if the formats are correct 
(EAN13 codes start with 978 or 979 for ISBN, and 977 for ISSN). 
•  Code ID Transmission: If this parameter is enabled, the Code ID selected 
by the preceding setting will be included in the data being transmitted. 
•  Application ID Transmission: If this parameter is enabled, the Application 
ID will be included in the data being transmitted. 
•  Checksum Transmission: If this parameter is enabled, the checksum 
character will be included in the data being transmitted. 
•  Checksum Transmission: If this parameter is enabled, the checksum 
character will be transmitted together with data. 
6.9 MSI 
•  Checksum Verification: Three kinds of checksum calculations can be 
implemented into MSI code : Single Modulo 10,  Double Modulo 10, or 
Modulo 11 & 10 checksum. If the checksum character is incorrect, the 
barcode will not be read. 
•  Checksum Transmission: User can control how the checksum is 
transmitted by configuring this parameter. 
1) Transmitted 
2) Last digit not transmitted 
3) Last 2 digits not transmitted 
•  Code Length Qualification: Because of the weak structure of the MSI 
code, a partial scan has a high probability of decoding as a valid but shorter 
MSI codes (known as short scan). To prevent this kind of undesired 
readings, the Code Length settings can help to ensure that the correct code is 
read by qualifying the allowable code length. Code length limitations can be 
set in 2 ways: Fixed Code Length and Max/Min code length. If the fixed 
code length is selected, up to 2 fixed lengths can be specified. And if max / 
min code length is selected, the max length and the min length must be 
specified, and the scanner will only accept those codes with lengths fall 
between max / min length specified. 
6.10 Plessey 
•  Convert to UK Plessey: If this parameter is enabled, the scanner will 
change each occurrence of the character ‘A’ into character ‘X’ in the code. 
24