User's Manual

64
Scanner Configuration SmartScan Manual
 Enter Setup 
 Download 
6) Run the download utility “ProLoad.exe” or “Download.exe” on your computer.   
(Download.exe requires version 2.3 or later!) 
Open the firmware update “1x66-xx.shx”, and select the correct COM port. 
 Baud rate    – 115,200 bps 
 Data bit    – 8 
 Parity   – None 
 Flow control   – None   
7) The scanner will automatically restart itself when upgrading firmware is completed successfully. 
USING 3667 OR GENERIC DONGLE 
1) Connect the 3667 cradle or any Bluetooth dongle to your computer via the USB port. 
2) Refer to section 1.6.1 for the target scanner to establish a connection with your computer via 
the 3667 cradle or a dongle. 
Read the following labels in sequence to configure the scanner to use Bluetooth Serial Port as 
output interface. 
 Enter Setup 
  Activate Bluetooth SPP (and read labels for PIN code…) 
 Update 
3) Same as steps 5 ~ 7 above. 