Specifications
Table Of Contents
- Contents
- Tables
- Figures
- 1 Introduction
- 2 Interface Characteristics
- 2.1 Application Interface
- 2.2 RF Antenna Interface
- 2.3 GNSS Antenna Interface
- 2.4 Sample Application
- 3 Operating Characteristics
- 4 Mechanical Dimensions, Mounting and Packaging
- 5 Regulatory and Type Approval Information
- 6 Document Information
- 7 Appendix
Cinterion
®
PLSx3 Hardware Interface Description
3.4 Power Supply
89
t PLSx3_HID_v01.002d 2021-08-24
Public / Released
Page 82 of 129
I
BATT+
2
(i.e., sum of
BATT+
BB
and
BATT+
RF
)
Average
GSM1800
supply current
5
GPRS Data transfer
GSM1800; PCL=0;
1Tx/4Rx
ROPR=8
(max. reduction)
209 mA
ROPR=4
(no reduction)
209 mA
GPRS Data transfer
GSM1800; PCL=0;
2Tx/3Rx
ROPR=8
(max. reduction)
295 mA
ROPR=4
(no reduction)
359 mA
GPRS Data transfer
GSM1800; PCL=0;
4Tx/1Rx
ROPR=8
(max. reduction)
433 mA
ROPR=4
(no reduction)
640 mA
EDGE Data transfer
GSM1800; PCL=0;
1Tx/4Rx
ROPR=8
(max. reduction)
163 mA
ROPR=4
(no reduction)
163 mA
EDGE Data transfer
GSM1800; PCL=0;
2Tx/3Rx
ROPR=8
(max. reduction)
250 mA
ROPR=4
(no reduction)
269 mA
EDGE Data transfer
GSM1800; PCL=0;
4Tx/1Rx
ROPR=8
(max. reduction)
420 mA
ROPR=4
(no reduction)
471 mA
Table 19: Current Consumption Ratings -GSM
1
Description Conditions Typical rating
(W,EP,LA,J, I)
Unit