Installation Guide
Table Of Contents
- Installation
- Addendum
- Webfleet Solutions Limited Warranty
Using the IN and OUT for changing the logbook mode
You can change the logbook mode using the IN/OUT of your LINK 740. Connect a normally open momen-
tary push button switch and an indicator light to the IN/OUT. This requires configuration in WEBFLEET. You
can use a normally open momentary push button switch and a separate indicator light or a switch with an
integrated indicator light.
Connect a normally open momentary push button switch and indicator light to the IN/OUT.
When you press the push button for a short time, the logbook mode switches to Private trip. Then the in-
dicator light will turn on. When you turn on the ignition the logbook mode switches back to Business trip.
Using the input IN for changing the logbook mode
Your LINK 740 can report logbook-relevant information to WEBFLEET. Using the input IN you can change
the logbook mode between private and business trips. This requires configuration in WEBFLEET.
Connect a latched switch to IN as shown below.
If the switch is on (connected to vehicle voltage), the logbook mode is set to Private trip. If the switch is
off (connected to GND), the logbook mode is set to Business trip.
Using the input IN for idle time reporting
Your LINK 740 can report idle times to WEBFLEET when the engine is running for longer than five minutes
and the vehicle is not moving. This requires configuration in WEBFLEET.
The input IN must be connected to a signal indicating the activity of the engine, for example alternator, en-
gine, etc. The input IN must be active when the engine is running.
31