Specifications
CINTERION
®
BGS12 Hardware Interface Description
Contents
98 of 109
Page
BGS12 HID_V00.915
Confidential / Released
2019
-
01
-
07
The label shown in Figure 57 summarizes requirements regarding moisture sensitivity, includ-
ing shelf life and baking requirements. It is attached to the outside of the moisture barrier bag.
Figure 57: Moisture Sensitivity Label
MBBs contain one or more desiccant pouches to absorb moisture that may be in the bag. The
humidity indicator card described below should be used to determine whether the enclosed
components have absorbed an excessive amount of moisture.
The desiccant pouches should not be baked or reused once removed from the MBB.
The humidity indicator card is a moisture indicator and is included in the MBB to show the ap-
proximate relative humidity level within the bag. Sample humidity cards are shown in Figure 58.
If the components have been exposed to moisture above the recommended limits, the units will
have to be rebaked.