Specifications

CINTERION
®
BGS12 Hardware Interface Description
Contents
69 of 109
Page
BGS12 HID_V00.915
Confidential / Released
2019
-
01
-
07
5 Electrical Reliability and Radio Characteristics
5.1 Absolute Maximum Ratings
The absolute maximum ratings stated in Table 17 are stress ratings under any conditions.
Stresses beyond any of these limits will cause permanent damage to BGS12.
Table 17: Absolute maximum ratings
Parameter Min Max Unit
Supply voltage BATT
+BB
, BATT
+RF
-0.3 +5 V
Voltage at all digital lines in Power Down mode -0.3 +0.3 V
Voltage at digital lines VDIG domain (2.8V) in normal
operation
-0.3 +3.3 V
Voltage at SIM interface, CCVCC 1.8V in normal
Operation
-0.3 +2.2 V
Voltage at SIM interface, CCVCC 3.0V in normal
Operation
-0.3 +3.3 V
Voltage at analog lines in normal operation -0.3 +3.0 V
Voltage at analog lines in Power Down mode -0.3 +0.3 V
VDDLP -0.3 +3.6 V
5.2 Operating Temperatures
Please note that the module’s lifetime, i.e., the MTTF (mean time to failure) may be reduced, if
operated outside the restricted temperature range. A special URC reports whether the module
enters or leaves the restricted temperature range (see [1]; AT^SCTM).
Table 18: Board temperature
Parameter Min Typ Max Unit
Normal operation -20 +25 +85 °C
Extended operation -40
+90 °C
Automatic shutdown
1
Temperature measured on BGS12
board
<-40
---
>+95
°C
1. Due to temperature measurement uncertainty, a tolerance of ±3°C on the thresholds may
occur.