Specifications
Table Of Contents
- Contents
- Tables
- Figures
- 1 Introduction
- 2 Interface Characteristics
- 2.1 Application Interface
- 2.1.1 Pad Assignment
- 2.1.2 Signal Properties
- 2.1.3 USB Interface
- 2.1.4 Serial Interface ASC0
- 2.1.5 Serial Interface ASC1
- 2.1.6 Inter-Integrated Circuit Interface
- 2.1.7 UICC/SIM/USIM Interface
- 2.1.8 Enhanced ESD Protection for SIM Interfaces
- 2.1.9 Digital Audio Interface
- 2.1.10 Analog-to-Digital Converter (ADC)
- 2.1.11 RTC Backup
- 2.1.12 GPIO Interface
- 2.1.13 Control Signals
- 2.1.14 JTAG Interface
- 2.1.15 eMMC Interface
- 2.2 GSM/UMTS/LTE Antenna Interface
- 2.3 GNSS Antenna Interface
- 2.4 Sample Application
- 2.1 Application Interface
- 3 GNSS Interface
- 4 Operating Characteristics
- 5 Mechanical Dimensions and Mounting
- 6 Regulatory and Type Approval Information
- 7 Document Information
- 8 Appendix
Cinterion
®
ALAS5V Hardware Interface Description
4.2 Power Up/Power Down Scenarios
96
ALAS5V_HID_v00.030a 2019-03-20
Confidential / Preliminary
Page 75 of 124
4.2.3.3 Turn off ALAS5V Using IGT Line
The IGT line can be configured for use in two different switching modes: You can set the IGT
line to switch on the module only, or to switch it on and off. The switching mode is determined
by the parameter "MEShutdown/OnIgnition" of the AT^SCFG command.
By factory default, the ON/OFF switch mode of IGT is disabled:
To configure IGT for use as ON/OFF switch:
Take great care before changing the switching mode of the IGT line. To ensure that the IGT
line works properly as ON/OFF switch it is of vital importance that the following conditions are
met:
Switch-on condition: If the ALAS5V is off, the IGT line must be asserted for at least 100 milli-
seconds before being released.
Switch-off condition: If the ALAS5V is on, the IGT line must be asserted for at least 2.1 sec-
onds before being released. The module switches off after the line is
released. The switch-off routine is identical with the procedure initiated
by AT^SMSO, i.e. the software performs an orderly shutdown as
described in Section 4.2.3.1.
Before switching off the module wait at least 32 seconds after startup.
Figure 30: Timing of IGT if used as ON/OFF switch
AT^SCFG=”MEShutdown/OnIgnition”
^SCFG: "MEShutdown/OnIgnition","off"
OK
# Query the current status of IGT.
# IGT can be used only to switch on ALAS5V.
IGT works as described in Section 4.2.1.
AT^SCFG=”MEShutdown/OnIgnition”,”on”
^SCFG: "MEShutdown/OnIgnition","on"
OK
# Enable the ON/OFF switch mode of IGT.
# IGT can be used to switch on and off ALAS5V.
1 2
>32s
> 100ms >2.1s
1– TriggersswitchONroutine
2– TriggersswitchOFFroutine
IGT