Specifications

FuzzyScan
Programming Manual
Configure Your FuzzyScan
31
PROGRAM
Operation Control
Flash Duty Cycle, Redundancy, Delay Setting
M_DEFAULT
Family Code Selection P.C Parameter Selection Option Code
Flash Duty Cycle
SS
SS
SS
SS
1/2 duty cycle
2/3 duty cycle
3/4 duty cycle
4/5 duty cycle
0
1
2
3
Redundancy (Scan Voting)
SS
SS
SS
SS
SS
SS
None
1 time
2 times
3 times
4 times
5 times
To prevent potential miss reading.
0
1
2
3
4
5
Reread Delay
SS
SS
SS
SS
SS
SS
Disable
Immediate time out
Short time out
Medium time out
Long time out
Force verification
0
1
2
3
4
5
Good Read Delay
SS
SS
SS
SS
SS
SS
SS
None
200 msec.
500 msec.
1 sec.
1.5 sec.
2 sec.
3 sec.
0
1
2
3
4
5
6
The Flash Duty Cycle is designed to control the flashing frequency of the light source.
The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted.
The Reread Delay is designed to inhibit FuzzyScan from reading the same bar code label twice in pre-defined short duration. Force Verification will not allow reading of the
same bar code twice.