Specifications

FuzzyScan
Programming Manual
Configure Your FuzzyScan
29
PROGRAM
Operation Control
Operation Mode Setting
M_DEFAULT
Family Code Selection P.C Parameter Selection Option Code
Operation Mode
SS
SS
SS
SS
SS
SS
SS
SS
Low Power mode (Low Power triggering)
Trigger mode/Serial mode (External triggering)
Presentation mode (Auto detection)
Alternative mode (Periodic power off)
Flash mode (Pulse driven reading)
Force mode (Continued power on)
Toggle mode (Repeat reading)
Diagnostic mode (Test reading)
0
1
2
3
4
5
6
7
Lower Power Mode (Low Power Triggering)
The scanner goes into idle state after scanning the bar code. You must press the trigger to wake up the scanner for operation. It is very helpful for mobile data collection
and application, which are concerned with power savings.
Trigger Mode/Serial Mode (External Triggering)
The scanner goes into standby state after scanning the bar code. You must press the trigger to turn on the light source of the scanner before scanning the bar code.
Presentation Mode (Auto Detection)
Presentation mode uses ambient light to detect bar codes. The LEDs are off for ambient conditions until a change occurs in the imager’s field of view. Then the LEDS turn
on automatically to read the bar code. If the light level in the room is not high enough, Presentation Mode may not work properly.
Alternative Mode (Periodic Power Off)
The scanner keeps the light source of the scanner turned on and disables the infrared sensor till the pre-defined auto power off duration is up. After the scanner turns off
the light source, you must press the trigger to turn on the light source again. After each good read, the auto power off timer counter is reset. You do not have to press the
trigger frequently, it is very convenient for multiple scanning.
Flash Mode (Pulse Driven Reading)
The scanner flashes the light source of the scanner without using the trigger. If the scanner detects an image which is similar to a bar code, the scanner forces on the light
source automatically and scans the bar code. Flash Duty Cycle adjustment can change the frequency of the blinking.
Force Mode (Continued Power On)
The light source of the scanner is forced on for continued operation without pressing the trigger switch. This mode is convenient for high speed bar code reading.
Toggle Mode (Repeat Reading)
The toggle mode is very similar to the Alternative Mode without the pre-defined auto power off duration concern. You must press the trigger to turn on the light source of the
scanner to scan. The scanner keeps the light source turned on until you press the trigger again.
Diagnostic Mode (Test Reading)
This operation mode is specifically designed for diagnostic purposes. When this operation mode is selected, the light source of the scanner is force on without regard for
other programmable parameters, such as reread delay, redundancy, and so forth.