BARCODE IMAGER Programming Manual International Edition, Rev.
FuzzyScan Programming Manual Revision History Rev. No. Released Date Rev.2.0 Beta Aug. 01, 2008 Rev.2.1 Beta Aug. 21, 2008 Page 29 Vibrator – Default value is changed from Disable to Enable. Page 31 Auto Power Off Duration – Default value is changed from Extremely long to Short Page 30 Rename “Pulse Driven Duty” to “Flash Duty Cycle” Page 31 Besides Alternative mode, the Auto Power Off Duration is also applicable to Presentation Mode and Flash Model.
Programming Manual FuzzyScan Rev. No. Released Date Rev. A1 Mar. 11, 2009 Description Page 30 Buzzer Tone Adjust – Cancel “Good-read beep before data transmission” and “Good-read beep after data transmission”. Page 30 Vibrator – Modify “Enable” to “short”, “medium”, “long” and “extremely long” vibration duration. Page 31 Reread Delay – Default value is changed from Short time out to Immediate time out. Page 32 Rename “Good Read Duration” to “Good Read Beep Duration”.
© Copyright Cino Group © Copyright PC Worth Int’l Co., Ltd Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains proprietary information that is protected by copyright.
Table of Contents Getting Started Getting Familiar with your FuzzyScan 1 Connecting/Disconnecting Cable 1 Connecting Host Interface 2 Configure Your FuzzyScan FuzzyScan Programming Manual Bar Code Programming Manual 3 Programming Procedures 4 Host Interface Selection 8 Symbology Reading Control 9 Keyboard Interface Control 21 Serial Interface Control 25 Wand Emulation Control 28 Operation Control 29 Condensed DataWizard 33 Appendix Keyboard Function Code Table 40 ASCII Input Sho
FuzzyScan Programming Manual Getting Started Getting Familiar with your FuzzyScan Connecting/Disconnecting Cable Thank you for choosing Cino FuzzyScan Imager. All FuzzyScan Imagers deliver world-class performance for a broad range of market applications to unleash your productivity. This document provides installation and programming instructions for FuzzyScan Imagers. FuzzyScan imagers provide PS/2(DOS/V) Keyboard Wedge, RS-232 Serial, USB interfaces capability.
Getting Started Connecting Host Interface FuzzyScan imagers have capability to connect different host devices by PS/2(DOS/V) Keyboard Wedge, RS-232 Serial and USB interfaces. Please choose one of the interface cables to connect your host device by referring to the illustrations below.
Configure Your FuzzyScan Bar Code Programming Menu The FuzzyScan bar code commands are specially designed Proprietary bar code labels which allow you to set the FuzzyScan internal programming parameters. There are System Command, Family Code and Option Code for programming purpose.
Configure Your FuzzyScan Programming Procedures FuzzyScan Programming Manual As you scan the bar code command to select the desired parameters, information about the final selected parameters represented by the bar code commands are stored in the FuzzyScan’s internal Flash Memory ASIC or non-volatile memory. If you turn off the unit, the Flash Memory ASIC or non-volatile memory retains all programming options.
Configure Your FuzzyScan Program & End System List, Group & Master Default Scan “PROGRAM” Scan “SYSLIST” FuzzyScan will enter programming mode, and inhibit all non-programming functions. FuzzyScan will list the product information and revision number to host via selected host interface, FuzzyScan Programming Manual then issue the completion beeping.
Configure Your FuzzyScan Single scan selection Multiple scans selection Scan Scan “PROGRAM” Scan One of Family Codes “PROGRAM” Enter programming mode. Select one of desired Scan One of Family Codes programming families. Select one of desired programming families. 1. Select one or several Select one option code of Scan One of Option Codes Enter programming mode. Scan One or Several Option Codes desired parameter. option codes to select desired parameters. 2.
Configure Your FuzzyScan Cycling scan selection Dual level selection Scan “PROGRAM” Scan One of Family Codes Scan “PROGRAM” Enter programming mode. Select one of desired Scan One of Family Codes programming families. Cycling select one or Scan One of Option Codes (1st) Scan Several Option Codes several option codes of desired parameters as “Single” or “Multiple” Programming Manual FuzzyScan (2nd) Scan One or Several Option Codes Scan “FIN” Finish cycling selection.
Configure Your FuzzyScan Host Interface Selection M_DEFAULT FuzzyScan Programming Manual PROGRAM Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ User Defined Symbol ID ♦ FuzzyScan Programming Manual PROGRAM M_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Symbology ID Transmission ♦ FuzzyScan Programming Manual PROGRAM M_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Readable Bar Code Setting ♦ PROGRAM Family Code Selection P.C Readable Symbology Setting SS CS CS CS CS CS CS CS CS CS CS CS CS CS CS Remember to scan “FIN” to terminate this selection. But if you select the Programming Manual “ Automatic discrimination ”, FuzzyScan M_DEFAULT FuzzyScan will terminate this selection automatically.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 39/Code 32 Setting ♦ FuzzyScan Programming Manual PROGRAM M_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Codabar/NW-7 Setting ♦ FuzzyScan Programming Manual PROGRAM M_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ UPC-A & UPC-E Setting ♦ FuzzyScan Programming Manual PROGRAM M_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ EAN/JAN & IATA Setting ♦ FuzzyScan Programming Manual PROGRAM M_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 25 Family & German Post Code Setting ♦ FuzzyScan Programming Manual PROGRAM M_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 11 & Code 93 Setting ♦ PROGRAM M_DEFAULT Family Code Selection P.C Parameter Selection Code 11 Setting SS SS SS SS SS Select 1-check digit verification Select 2-check digit verification Disable check digit transmission Enable 1-check digit transmission Enable 2-check digit transmission Code 11 Min.
Configure Your FuzzyScan Symbology Reading Control ♦ MSI/Plessey, Code 128 & UCC/EAN 128 Setting ♦ PROGRAM M_DEFAULT Family Code Selection P.C Parameter Selection MSI/Plessey Setting SS SS SS SS SS SS Select MOD 10 check digit Select MOD 10-10 check digit Select MOD 11-10 check digit Disable check digit transmission Enable 1-check digit transmission Enable 2-check digit transmission MSI/Plessey Min.
Configure Your FuzzyScan Symbology Reading Control ♦ UK/Plessey & Telepen Setting ♦ PROGRAM M_DEFAULT Family Code Selection P.C Parameter Selection UK/Plessey Setting SS SS SS SS SS SS Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F Disable check digit transmission Enable check digit transmission UK/Plessey Min.
Configure Your FuzzyScan Symbology Reading Control ♦ GS1 DataBar Setting ♦ PROGRAM M_DEFAULT Family Code Selection P.C Parameter Selection GS1 DataBar Setting SS SS SS SS SS SS Disable GS1 DataBar (RSS-14) decoder Enable GS1 DataBar (RSS-14) decoder Disable GS1 DataBar limited decoder Enable GS1 DataBar limited decoder Disable GS1 DataBar expanded decoder Enable GS1 DataBar expanded decoder GS1 DataBar Min.
Configure Your FuzzyScan Keyboard Interface Control ♦ Keyboard Layout (Language) Setting ♦ FuzzyScan Programming Manual PROGRAM M_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Keyboard Interface Control ♦ Record Suffix, Preamble, Postamble & Caps Lock ♦ PROGRAM M_DEFAULT Family Code Selection P.C Parameter Selection Record Suffix SS SS SS SS SS SS None RETURN TAB SPACE ENTER (Numeric Key Pad) User defined character (1 character) Preamble SS MS None 1-15 characters Option Code 0 1 2 3 4 5, (00-7F) FIN [00-7f], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection.
Configure Your FuzzyScan Keyboard Interface Control ♦ Delay Setting ♦ PROGRAM M_DEFAULT Family Code Selection P.C Intermessage Delay SS MS Parameter Selection None 1-99 (x5) msec. Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Intercharacter Delay SS MS None 1-99 (x5) msec. FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Configure Your FuzzyScan Keyboard Interface Control ♦ Emulation Setting & Upper/Lower Case Setting ♦ PROGRAM M_DEFAULT Family Code Selection P.C Function Key Emulation SS SS Parameter Selection Enable ASCII 00-31 code as keyboard function code output Ctrl-Output Option Code 0 1 FuzzyScan Programming Manual Refer to Appendix – Keyboard Function Code Table for details.
Configure Your FuzzyScan Serial Interface Control ♦ Record Suffix, Preamble ,Postamble Setting ♦ PROGRAM M_DEFAULT Family Code Selection P.C STX/ETX Control SS SS Parameter Selection Option Code Disable STX/ETX transmission Enable STX/ETX transmission 0 1 FuzzyScan Programming Manual STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.
Configure Your FuzzyScan Serial Interface Control ♦ Delay Setting ♦ PROGRAM M_DEFAULT Family Code Selection P.C Intermessage Delay SS MS Parameter Selection None 1-99 (x5) msec. Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Intercharacter Delay SS MS None 1-99 (x5) msec. FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Configure Your FuzzyScan Serial Interface Control ♦ Protocol, Baud Rate, Data Frame & Time Out Setting ♦ FuzzyScan Programming Manual PROGRAM M_DEFAULT Family Code Selection P.C Parameter Selection Option Code Handshaking Protocol SS SS SS SS None (free running mode) RTS/CTS (hardware handshaking) ACK/NAK (software handshaking) Xon/Xoff (software handshaking) Baud Rate (BPS) SS SS SS SS 38.4K BPS 19.
Configure Your FuzzyScan Wand Emulation Control ♦ Output Polarity, Signal State, Margin/Module Time, etc. ♦ PROGRAM M_DEFAULT Family Code Selection P.C Output Polarity SS SS Parameter Selection Option Code High level (5Vdc) on Bar (low level on Space) Low level (0Vdc) on Bar (high level on Space) 0 1 Determine the output voltage level for both bar and space.
Configure Your FuzzyScan Operation Control ♦ Operation Mode Setting ♦ FuzzyScan Programming Manual PROGRAM M_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control ♦ Buzzer, Indicator, Vibrator, Inverse Reading, Dollar Sign ♦ FuzzyScan Programming Manual PROGRAM M_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control ♦ Flash Duty Cycle, Redundancy, Delay Setting ♦ FuzzyScan Programming Manual PROGRAM M_DEFAULT Family Code Selection P.C Parameter Selection Option Code Flash Duty Cycle SS SS SS SS 1/2 duty cycle 2/3 duty cycle 3/4 duty cycle 4/5 duty cycle 0 1 2 3 Redundancy (Scan Voting) SS SS SS SS SS SS None 1 time 2 times 3 times 4 times 5 times To prevent potential miss reading.
Configure Your FuzzyScan Operation Control ♦ Time-out Setting, Good Read Beep Duration ♦ FuzzyScan Programming Manual PROGRAM M_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Condensed DataWizard ♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦ PROGRAM M_DEFAULT Family Code Selection P.C Preamble SS MS Parameter Selection None 1-15 characters Option Code FIN [00-7f], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection. Postamble SS MS None 1-15 characters FIN [00-7f], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection.
Configure Your FuzzyScan Condensed DataWizard ♦ Data Formatter Setting ♦ PROGRAM Family Code Selection P.
Configure Your FuzzyScan Condensed DataWizard ♦ Data Verifier Setting ♦ PROGRAM M_DEFAULT Family Code Selection P.C Verifier Control SS MS MS Identified Data Length SS DS Parameter Selection Option Code 2nd Option Code Disable Select one bar code symbology Select all bar code symbologies FIN (2 digits) 00 automatic termination automatic termination Disable Enable FIN (2 digits) Determine the identified data length for verification.
Configure Your FuzzyScan Condensed DataWizard ♦ Data Replacer Setting ♦ PROGRAM Family Code Selection P.
Configure Your FuzzyScan Condensed DataWizard ♦ Data Organizer Setting ♦ PROGRAM Family Code Selection P.
Configure Your FuzzyScan Select a Bar Code Symbology Application Example You can select one or all types of bar code symbologies to use Condensed DataWizard for advanced transmission arrangement. If you scan “00” to select all types, the FuzzyScan will arrange all incoming data to meet your pre-defined format. If you want to select only one type bar code, please select one of the option code listed below.
Configure Your FuzzyScan Programming Procedure [Data Verifier] [Data Replacer] Scan “Program” to enter the programming mode. Scan “Replacer Control” and set bar code symbology to “48”. Scan “Verifier Control” and set bar code symbology to “48” (Interleaved 2 of 5). Scan “1st Replacement” and set the identified position to “00”, then replaced character to “41” (Hex Code of A). Scan “Identified Data Length” and set the length to “16”.
Appendix FuzzyScan Programming Manual Keyboard Function Code Table No. ANSI ASCII 00 NUL 00H 01 SOH 02 Key Function No.
Appendix ASCII Input Shortcut To configure the user definable parameters of FuzzyScan via programming menu, FuzzyScan will ask you to scan your desired ASCII value in HEX form. You have to refer to the “HEX/ASCII Table” for details. HEX/ASCII Reference Table H 0 1 2 3 4 5 6 7 0 NUL DLE SPACE 0 @ P ` p Example: 1 SOH DC1 ! 1 A Q a q If you want the scanned data output leading with a Dollar Sign, you have to set the “Preamble” to “$”.
Appendix Host Interface Quick Set PS/2 (DOS/V) Keyboard Wedge RS232 Serial Interface USB HID Interface Keyboard Replacement USB COM Interface FuzzyScan Programming Manual Operation Mode Quick Set Lower Power Mode Force Mode Alternative Mode Trigger Mode Toggle Mode Flash Mode Presentation Mode Diagnostic Mode 42
Appendix Option Codes 0 8 4 C 1 9 5 D FuzzyScan Programming Manual 2 A 6 E 3 B 7 F FIN (Finish) END (Exit) 43
Appendix System Commands System Information List (SYSLIST) PROGRAM (Enter Programming Mode) Save User Default FIN (Finish) Factory Default (M_DEFAULT) FuzzyScan Programming Manual User Default END (Exit Programming Mode) PowerTool Host Link 44
www.cino.com.tw FuzzyScan Family Programming Manual CINO GROUP PC WORTH INT’L CO., LTD.