FUZZYSCAN FAMILY Quick Start Guide BARCODE SCANNER
Getting Familiar with Your FuzzyScan Thank you for choosing Cino FuzzyScan Bar Code Scanner. All FuzzyScan scanners deliver world-class performance for a broad range of applications to unleash your productivity. In order to fulfill your various requirements, the options of Vibrator, PDF Readability and Disinfectant-ready Housing are available upon request. For more details, please visit our website or contact your supplier. This document provides an easy reference for installation and operation purpose.
Connecting to Your Host FuzzyScan scanners support USB, PS/2(DOS/V) Keyboard Wedge and RS-232 Serial interfaces. Please choose your desired interface cable, then plug it into the cable interface port of the scanner and connect it to the host. If you would like to remove the cable, please straighten one end of a paper clip, then insert it into the cable release hole to pull out the cable.
Using Accessories You can enhance productivity of your workforce by using various accessories to fulfill a wide variety of application demand. Universal Holder The stylish Universal Holder is designed for storing your scanner when not in use. It serves to protect the scanner from lens-scratched or falling. Moreover, its artistic-design enhances the entire value of the scanner. Hand-free SmartStand SmartStand is specifically designed for hand-free applications to maximize user’s comfort and productivity.
Operation Modes Both F series Linear Imager and L series Laser Imager are available in FuzzyScan family. Both series support different operation mode which are listed below for reference. The F series supports nine operation modes, including trigger, presentation, alternative, level, flash, force, toggle, diagnostic and low power modes. The L series supports five operation modes, including trigger, presentation, alternative, level and low power modes.
Flash Mode When flash mode is selected, the scanner flashes the light source without having to press the trigger switch. If the scanner detects an image which is similar to a bar code, it forces on the light source automatically and scans the bar code. Force Mode When force mode is selected, the light source of the scanner is forced on for continued operation without having to press the trigger switch. This mode is convenient for high speed bar code reading.
Keyboard Interface Quick Set - Record Suffix - None RETURN ◆ TAB SPACE ENTER - Keyboard Layout - USA ◆ France Germany United Kingdom-UK Canadian French Spain (Spanish) Spain (Latin America) Nertherlands Japan Sweden/Finland 6
Serial Interface Quick Set - Record Suffix - None TAB LF CR ◆ SPACE CRLF - Baud Rate – 115.2K BPS 4800 BPS 19.2K BPS 57.6K BPS 2400 BPS 9600 BPS ◆ 38.
System Commands System Information Master Default PowerTool Host Link User Default Factory Default Save User Default Host Interface Quick Set RS232 Serial Keyboard Replacement PS/2 (DOS/V) KBW Standard Mode PS/2 (DOS/V) KBW Turbo Mode USB HID Standard Mode ◆ USB HID Turbo Mode USB Com Port Emulation 8
System Commands PROGRAM (Enter Programming Mode) END (Exit Programming Mode) Option Codes 0 A 6 1 B 7 2 C 8 3 D 9 4 E 5 F FIN (Finish) 9
Keyboard Interface Control Command Keyboard Layout Record Suffix Parameter Selection ◆ Latin America Italy Netherlands Denmark Belgium Switzerland-Germany Iceland Japan Czech 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 None RETURN TAB SPACE ENTER User define character 0 1 2 3 4 5 ◆ ◆ Preamble None 1-15 characters Postamble None 1-15 characters Intermessage Delay None 1-99 (x5) msec. Intercharacter Delay None 1-99 (x5) msec. Interfunction Delay None 1-99 (x5) msec.
Serial Interface Control Command Parameter Selection STX/ETX Control Disable STX/ETX transmission Enable STX/ETX transmission Record Suffix None CR LF CRLF Option Code ◆ 0 1 TAB SPACE User define character ◆ 0 1 2 3 ◆ Preamble None 1-15 characters Postamble None 1-15 characters FIN [00-7F], [FIN] ◆ Handshaking Protocol FIN [00-7F], [FIN] ◆ None RTS/CTS ACK/ NAK Xon/Xoff 0 1 2 3 ◆ Intermessage Delay None 1-99 (x5) msec. Intercharacter Delay None 1-99 (x5) msec.
Operation and Output Control Command Inverse Reading Disable Enable Redundancy None Level 1 Level 2 Level 3 Level 4 Level 5 Parameter Selection ◆ Option Code 0 1 0 1 2 3 4 5 ◆ To prevent potential miss reading.
Operation and Output Control Command Trigger Control Parameter Selection Enable left trigger, disable right trigger Enable right trigger, disable left trigger Enable left and right triggers ◆ Option Code 0 1 2 Only available for FuzzyScan F460/F468. ◆ Scan Rate Control Dynamic Fixed Good Read Delay None 200 msec. 500 msec. 1 sec. 1.5 sec. 2 sec. 3 sec.
Keyboard Function Code Table No. ANSI ASCII Key Function No.
www.cino.com.tw FuzzyScan Barcode Scanner Quick Start Guide International Edition, Rev. B2 P/N: YMAUB00010030R0 Disclaimer Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this publication.