FIXED MOUNT SCANNER Programming Manual International Edition, Rev.
Revision History Rev. No. Released Date Rev. A May 26, 2010 First Release Rev. A1 Jun. 18, 2010 Page 16 Page 38 Add “UPC/EAN Security Level” Add “Immediate” parameter (option 5) to "Time Delay to Low Power Mode" and change the default value from 5 seconds to immediate.
© Copyright Cino Group © Copyright PC Worth Int’l Co., Ltd Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains proprietary information that is protected by copyright.
Table of Contents Getting Started Getting Familiar with Your FuzzyScan Connect to Your Host Install Your FuzzyScan Use the Test Mode Use Your FuzzyScan 1 2 3 4 5 FuzzyScan Fixed Mount Scan Programming Manual Configure Your FuzzyScan Bar Code Programming Manual Programming Procedures Host Interface Selection Symbology Reading Control Keyboard Interface Control Serial Interface Control Operation Control Condensed DataWizard 7 8 12 13 32 36 39 46 Appendix Symbology ID Table Keyboard Function Code Table AS
Getting Familiar with Your FuzzyScan Thank you for choosing Cino FuzzyScan FM400 Series Fixed Mount Scanner. Integrated with the innovative FuzzyScan 2.0 Imaging Technology and durable ultra-compact design, FM400 series not only provides outstanding reading performance, but also meets various demands for both industrial and general purpose applications. This document provides a quick reference for installation and operation purpose. The complete documentation is available at www.cino.com.tw.
Connect to Your Host Both RS232 and USB interfaces are available in different models of FM400 series. Each model is equipped with corresponding connector to meet various application demands. USB Models (FM4xx-11x) Universal Models (FM4xx-98x) The USB models provide a plug-and-play solution. Both USB HID and USB COM Port Emulation interfaces are available for user’s choice. The universal models support RS232 and USB interfaces with OK/NG signal outputs and external trigger input.
Install Your FuzzyScan Adjust Reading Angle Mount Your FuzzyScan The readability may be impacted by the specular reflection caused by the perpendicular reading angle. To get the most optimal reading performance, you are suggested to install the FM400 at an approximate 15° angle to the perpendicular line of the target barcode. However, the reading angle and distance may vary depending on the size and printing quality of barcodes.
Use the Test Mode The FuzzyScan FM400 provides an useful test mode which is helpful for you to quickly identify the best mounting position. Please refer to the descriptions listed below for details. Test Button Under normal operation, the Test Button of FM400 just acts as a normal trigger switch of hand-held scanner. You can press the Test Button to scan the corresponding barcode commands to configure your scanner with ease.
Use Your FuzzScan Both FuzzyScan Barcode commands and Serial commands are available to configure your FM400. The FuzzyScan barcode commands are a series of proprietary barcodes which allow you to easily configure the scanner for most applications. Moreover, the FuzzyScan serial commands are ideal for precise and complicated reading control in machine-controllable environments. Please refer to the relevant documentations for details.
is performed or the preset scan input time-out is up. Once the light source goes off, the scanner is waiting for the next trigger to activate scanning again. Trigger mode Under trigger mode, the scanner will turn on the light source to read barcode when it receives an external trigger or a serial trigger ON command.
Bar Code Programming Menu System Command The FuzzyScan bar code commands are specially designed Proprietary bar code labels which allow you to set the FuzzyScan internal programming parameters. There are System Command, Family Code and Option Code for programming purpose.
Programming Procedures FuzzyScan Fixed Mount Scan Programming Manual As you scan the bar code command to select the desired parameters, information about the final selected parameters represented by the bar code commands are stored in the FuzzyScan’s internal Flash Memory ASIC or non-volatile memory. If you turn off the unit, the Flash Memory ASIC or non-volatile memory retains all programming options.
Program & End System List, Group & Master Default Scan “PROGRAM” Scan “SYSLIST” FuzzyScan will enter programming mode, and inhibit all non-programming functions. FuzzyScan will list the product information and revision number to host via selected host interface, FuzzyScan Fixed Mount Scan Programming Manual then issue the completion beeping.
Single scan selection Scan “PROGRAM” Scan One of Family Codes Multiple scans selection Scan “PROGRAM” Enter programming mode. Select one of desired Select one of desired Scan programming families. One of Family Codes programming families. 1. Select one or several Select one option code of Scan One of Option Codes Enter programming mode. Scan One or Several Option Codes desired parameter. option codes to select desired parameters. 2.
Cycling scan selection Dual level selection Scan “PROGRAM” Scan One of Family Codes Scan “PROGRAM” Enter programming mode. Select one of desired Scan One of Family Codes programming families. Cycling select one or Scan One of Option Codes desired parameters as FuzzyScan Fixed Mount Scan Programming Manual (2nd) Scan One or Several Option Codes Scan “FIN” of desired parameters. 1. Select one or several parameters. 2. If it’s necessary, scan Finish cycling selection.
Host Interface Selection FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.
Symbology Reading Control ♦ User Defined Symbol ID ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.
Symbology Reading Control ♦ Symbology ID Transmission ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.
Symbology Reading Control ♦ Readable Bar Code Setting ♦ PROGRAM Family Code Selection P.C Readable Symbology Setting SS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS Remember to scan “FIN” to terminate FuzzyScan Fixed Mount Scan Programming Manual F_DEFAULT this selection. But if you select the “ Auto ”, FuzzyScan will terminate this selection automatically.
Symbology Reading Control ♦ Code 39/Code 32 Setting ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.
Symbology Reading Control ♦ Code 39 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Code 39 Security Level SS SS SS SS Parameter Selection Level 0 Level 1 Level 2 Level 3 Option Code 0 1 2 3 FuzzyScan Fixed Mount Scan Programming Manual Code 39 Security Level The scanner offers four levels of decode security for Code39 bar codes: Level 0: If you are experiencing misread of poorly-printed or serious out-of-spec. bar codes in level 1, please select level 0.
Symbology Reading Control ♦ Codabar/NW-7 Setting ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.
Symbology Reading Control ♦ UPC-A & UPC-E Setting ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.
Symbology Reading Control ♦ UPC-A & UPC-E Setting , Supplement Scan Voting♦ ♦ PROGRAM F_DEFAULT Family Code Selection P.
Symbology Reading Control ♦ EAN Setting , Supplement , Supplement Scan Voting♦ ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.
Symbology Reading Control ♦ UPC/EAN Security Level Setting , EAN Supplement Control♦ ♦ PROGRAM Family Code Selection P.
Symbology Reading Control ♦ UCC Coupon Extended Code Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C UCC Coupon Extended Code SS SS Parameter Selection Disable UCC Coupon Extended Code Enable UCC Coupon Extended Code Option Code 0 1 FuzzyScan Fixed Mount Scan Programming Manual UCC Coupon Extended Code When UCC coupon extended code function is enabled, scanner decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99” and UCC/EAN-128 Coupon Codes.
Symbology Reading Control ♦ IATA & Interleaved 2 of 5 Setting ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.
Symbology Reading Control ♦ Code 25 Family Setting ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.
Symbology Reading Control ♦ Code 11 & Code 93 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Code 11 Setting SS SS SS SS SS SS SS Disable Code 11 Enable Code 11 Disable check digit verification Select 1-check digit verification Select 2-check digit verification Disable check digit transmission Enable check digit transmission Code 11 Min.
Symbology Reading Control ♦ MSI/Plessey Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection MSI/Plessey Setting SS SS SS SS SS SS SS Disable MSI/Plessy Enable MSI/Plessy Select MOD 10 check digit Select MOD 10-10 check digit Select MOD 11-10 check digit Disable check digit transmission Enable check digit transmission MSI/Plessey Min.
Symbology Reading Control ♦ Code 128 & UCC/EAN 128 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Code 128/EAN-128 Setting SS SS SS SS SS SS Disable Code 128 and UCC/EAN-128 Enable Code 128 and UCC/EAN-128 Disable function code conversion Enable function code conversion ISBT Concatenation Off ISBT Concatenation On Code 128/EAN-128 Min.
Symbology Reading Control ♦ UK/Plessey Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection UK/Plessey Setting SS SS SS SS SS SS SS SS Disable UK/Plessey Enable UK/Plessey Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F Disable check digit transmission Enable check digit transmission UK/Plessey Min.
Symbology Reading Control ♦ Telepen Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Telepen Setting SS SS SS SS SS SS Disable Telepen Enable Telepen Select Telepen Numeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission Telepen Min.
Symbology Reading Control ♦ GS1 DataBar Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection GS1 DataBar Setting SS SS SS SS SS SS Disable GS1 DataBar (RSS-14) Enable GS1 DataBar (RSS-14) Disable GS1 DataBar Limited Enable GS1 DataBar Limited Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded GS1 DataBar Min. Length SS MS Default (04) 01-Maximum Option Code 0 1 2 3 4 5 FIN (2 digits) Only available for Expanded GS1 Databar.
Symbology Reading Control ♦ Linear-stacked & Korea Post Code Setting ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.
Keyboard Interface Control ♦ Keyboard Layout (Language) Setting ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.
Keyboard Interface Control ♦ Record Suffix, Preamble, Postamble & Caps Lock ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Record Suffix SS SS SS SS SS SS None RETURN TAB SPACE ENTER (Numeric Key Pad) User defined character (1 character) Preamble SS MS None 1-15 characters Option Code 0 1 2 3 4 5, (00-7F) FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection.
Keyboard Interface Control ♦ Delay Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Intermessage Delay SS MS Parameter Selection None 1-99 (x5) msec. Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Intercharacter Delay SS MS None 1-99 (x5) msec. FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Keyboard Interface Control ♦ Emulation Setting & Upper/Lower Case Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Function Key Emulation SS SS Parameter Selection Enable ASCII 00-31 code as keyboard function code output Ctrl-Output Option Code 0 1 FuzzyScan Fixed Mount Scan Programming Manual Refer to Appendix – Keyboard Function Code Table for details.
Serial Interface Control ♦ Record Suffix, Preamble, Postamble Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C STX/ETX Control SS SS Parameter Selection Option Code Disable STX/ETX transmission Enable STX/ETX transmission 0 1 FuzzyScan Fixed Mount Scan Programming Manual STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.
Serial Interface Control ♦ Delay Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Intermessage Delay SS MS Parameter Selection None 1-99 (x5) msec. Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Intercharacter Delay SS MS None 1-99 (x5) msec. FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Serial Interface Control ♦ Protocol, ACK/NAK Setting ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.
Serial Interface Control ♦Time Out Setting, Baud Rate, Data Frame♦ ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code Serial Response Time-out SS SS SS MS None 200 mseconds 500 mseconds 1 second 2 seconds 5 seconds User defined value (seconds) 0 1 2 3 4 5 6, (2 digits) Baud Rate (BPS) SS SS SS SS 38.4K BPS 19.2K BPS 9600 BPS 4800 BPS 2400 BPS 1200 BPS 57.6K BPS 115.
Operation Control ♦ Operation Mode Setting ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.
Operation Control ♦ Buzzer, Indicator, Inverse Reading♦ ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.
Operation Control ♦Dollar Sign, Redundancy, Scan Rate Control ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Dollar Sign Control SS SS SS SS SS Dollar sign output as “ $ “ Dollar sign output as “ “ Dollar sign output as “ € “ Dollar sign output as “ £ “ Dollar sign output as “ ¢ “ 0 1 2 3 4 Redundancy SS SS SS SS SS SS None Level 1 Level 2 Level 3 Level 4 Level 5 To prevent potential miss reading.
Operation Control ♦ Delay Setting ♦ F_DEFAULT PROGRAM Family Code Selection P.C Reread Delay SS SS SS SS SS SS Disable Immediate time out Short time out Medium time out Long time out Force verification 0 1 2 3 4 5 SS SS SS SS SS SS SS None 200 msec. 500 msec. 1 sec. 1.5 sec. 2 sec. 3 sec.
Operation Control ♦ Time-out and Duration Setting ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Scan Input Time-out SS SS SS SS SS MS 100 msec. 200 msec. 300 msec. 400 msec. 500 msec. Hands Free Time-out SS SS SS SS SS Short Medium Long Extremely long Disable 0 1 2 3 4 Good Read Duration SS SS SS SS SS Short Medium Long Extremely long Extremely short 0 1 2 3 4 600 msec. 700 msec. 800 msec. 900 msec.
Operation Control ♦ Presentation Scanning Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Presentation Sensitivity SS SS SS SS SS Parameter Selection Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7 Option Code 0 1 2 3 4 5 6 FuzzyScan Fixed Mount Scan Programming Manual The presentation sensitivity is used to configure the sensitivity level when the scanner is set as presentation mode. The higher lever means higher sensitivity for detecting the barcode.
Operation Control ♦ OK/NG Signal and Beeping Control ♦ FuzzyScan Fixed Mount Scan Programming Manual PROGRAM F_DEFAULT Family Code Selection P.
FuzzyScan Fixed Mount Scan Programming Manual The OK/NG Signal Active State can control the logic level in digit circuits design, you can adjust the active-high or active-low state for OK and NG signal outputs. The OK and NG signals are NPN outputs. The OK/NG Signal Output Control can control the OK/NG signal outputs and OK/NG indications of the scanner. If you disable OK or NG signal output, the scanner OK or NG indication will be disabled.
Condensed DataWizard ♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦ PROGRAM F_DEFAULT Family Code Selection P.C Preamble SS MS Parameter Selection None 1-15 characters Option Code FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection. Postamble SS MS None 1-15 characters FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection.
Condensed DataWizard ♦ Data Formatter Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Formatter Control SS MS MS 1st Insertion SS DS Parameter Selection Option Code 2nd Option Code Disable Select one bar code symbology Select all bar code symbologies FIN (2 digits) 00 automatic termination automatic termination Disable Enable FIN (2 digits) [1-3 characters], [FIN] 2-digits identified position; max.
Condensed DataWizard ♦ Data Verifier Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Verifier Control SS MS MS SS DS Identified Data Length Parameter Selection Option Code 2nd Option Code Disable Select one bar code symbology Select all bar code symbologies FIN (2 digits) 00 automatic termination automatic termination Disable Enable FIN (2 digits) Determine the identified data length for verification.
Condensed DataWizard ♦ Data Replacer Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.
Condensed DataWizard ♦ Data Organizer Setting ♦ PROGRAM Family Code Selection P.
[Data Verifier, Data Replacer, Data Organizer] Select a Bar Code Symbology If there is a 11-character data string, please refer to the following to calculate the actual position for identification. FuzzyScan Fixed Mount Scan Programming Manual You can select one or all types of bar code symbologies to use Condensed DataWizard for advanced transmission arrangement. If you scan “00” to select all types, the FuzzyScan will arrange all incoming data to meet your pre-defined format.
Programming Procedure [Data Verifier] [Data Replacer] Scan “Program” to enter the programming mode. Scan “Replacer Control” and set bar code symbology to “48”. Scan “Verifier Control” and set bar code symbology to “48” (Interleaved 2 of 5). Scan “1st Replacement” and set the identified position to “00”, then replaced character to “41” (Hex Code of A). FuzzyScan Fixed Mount Scan Programming Manual Scan “Identified Data Length” and set the length to “16”.
Symbology ID Table Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character c = Code Character m = Modifier Character Cino ID Code Family Primary Format AIM ID Code Code Modified Character Character Character UPC-A UPC-A with 2 supple. A UPC-A with 5 supple. UPC E UPC-E UPC-E with 2 supple. E UPC-E with 5 supple. FuzzyScan Fixed Mount Scan Programming Manual Cino ID Code Family m EAN/JAN-8 1 EAN/JAN-8 with 2 supple. 2 EAN/JAN-8 with 5 supple.
FuzzyScan Fixed Mount Scan Programming Manual Keyboard Function Code Table No. ANSI ASCII 00 NUL 00H 01 SOH 02 Key Function No.
ASCII Input Shortcut To configure the user definable parameters of FuzzyScan via programming menu, FuzzyScan will ask you to scan your desired ASCII value in HEX form. You have to refer to the “HEX/ASCII Table” for details. HEX/ASCII Reference Table H 0 1 2 3 4 5 6 7 0 NUL DLE SPACE 0 @ P ` p Example: 1 SOH DC1 ! 1 A Q a q If you want the scanned data output leading with a Dollar Sign, you have to set the “Preamble” to “$”.
Host Interface Quick Set RS232 Serial USB Com Port Emulation USB HID Standard Mode FuzzyScan Fixed Mount Scan Programming Manual USB HID Turbo Mode Operation Mode Quick Set Trigger Mode Force Mode (Continued power on) Alternative Mode (Periodic power off) Presentation Mode (Auto sensing) Level Mode (Auto power off) 59
Option Codes 0 8 4 C 1 9 5 D FuzzyScan Fixed Mount Scan Programming Manual 2 A 6 E 3 B 7 F FIN (Finish) END (Exit) 60
System Commands PROGRAM (Enter Programming Mode) System Information List (SYSLIST) Save User Default FIN (Finish) PowerTool Host Link FuzzyScan Fixed Mount Scan Programming Manual User Default END (Exit Programming Mode) Factory Default Master Default Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value.
Indications Power Indicator Status Indicator OK/NG Indicator Normal Operation Power on Power Steady blue Indicators Status Off Off Power on beep Good read (OK reading) Off Off 1 green blink 1 good read beep No read (NG reading) Off Off 1 red blink 1 no read beep 100% Indicators Status Steady Green OK/NG Steady Green 80 to 99% Steady Red Steady Green Steady Green Steady Red 20 to 49% Steady Orange Steady Orange 0 to 19% Steady Red Steady Red FuzzyScan Fixed Mount Scan Programm
www.cino.com.tw Fixed Mount Scanner Programming Manual CINO GROUP PC WORTH INT’L CO., LTD.