User guide

FuzzyScan Fixed Mount Scan
Programming Manual
76
[Data Replacer]
Scan “Replacer Control” and set bar code symbology to
48”.
Scan “1st Replacement” and set the identified position to
00”, then replaced character to “41” (Hex Code of A).
[Data Organizer]
Scan “Organizer Control” and set bar code symbology to
48”.
Scan “1st Organization” and set the identified position to
16”, then set the data transmission to “0” (forward).
Scan “2nd Organization” and set the identified position to
17”, then set the data transmission to “1” (backward).
Scan “END” (Exit) to terminate the programming.
[Important Notice]
Please note that Condensed DataWizard will follow the
preset working flow as below:
Verifier
Formatter
Replacer
Organizer
So when you set the identified position in Data Organizer,
you must consider the inserted data which you already set
via Data Formatter.
.