User`s manual

NexSens Technology, Inc.
iSIC User‟s Manual 17
After installation, selectStart | All Programs | AirLink Communications | Setup Wizard”.
Click next and select the COM Port the modem is connected to and click Next. You can leave the
“Auto Detect Port Settings” checked.
If the modem fails to detect, first verify you are using the correct COM port and then uncheck
the box and select 9600 from the Baud Rate. You can leave the Data Bits at 8, Parity at None,
Stop Bits at 1 and Flow Control at None.
If the problem persists, try closing the Setup Wizard, cycling power to the iSIC, and trying again.
Make sure the correct COM port is selected, and the serial cables are securely attached. Make
sure the A77 3100-iSIC Programming Cable is securely connected between the Modem cable
coming out of the back of the iSIC and the cable coming from the PC running the Setup Wizard.
The program will then connect to the modem. After it successfully finds the modem it will display
the modem information. Make sure this information is correct and click Next. If a Raven modem
is not detected, close and re-run the setup wizard.
If the modem settings come back blank, close the setup wizard, and cycle power to the iSIC by
removing the two fuses before retrying the Setup Wizard.