User manual
9.0 WEB USER INTERFACE
R599791 - FORCE 3D User Manual 81
Active column accordingly.
RTE Listing Window
•To add a System Event
1) Click Add to open the RTE Wizard.
2) Select the System Event tab.
3) Select a type of event from the System Event drop-down list. NOTE: Depending on the selection made,
additional selections are made available in the second drop-down list located underneath (i.e. Input Change >
Input 1, Slot 1).
Add System Event
•To Add a GPIO Event
1) Click Add to open the RTE Wizard.
2) Select the GPIO Event tab.
3) For the GPIO Event option define the Input Condition field as required. The Input Condition field contains 7
blocks which refer to the 7 I/O pins on the GPIO connector. Pin 1 = +12V and Pin 5 = Ground are not included or
changed. 2) Clicking a block toggles between H, L, and X as shown in Figure below.
Add a GPIO Event
•To Add a Function Key Event
1) Click Add to open the RTE Wizard.
2) Select the Function Key Event tab.
3) Select a Function key from the drop-down list










