20.
If the alarm still indicates a yellow flash with a single beep or the low battery icon is
displayed on display alarms the batteries may be depleted. Replace with fresh
batteries. If the red, amber & green lights do not flash in sequence and there is
no display on the LCD display units the batteries may be installed incorrectly
(reverse polarity). Remove the Alarm from the mounting bracket, remove the
battery cover and check if the batteries are installed correctly. If the batteries
were connected incorrectly and after correcting the polarity of the batteries,
for the first hour the Alarm may indicate CO is present by a flashing red LED
for non-display Alarms; for display models the Alarm may indicate CO level
readings and/or random icons. Please note that during this period the Alarm
will still activate as required during an actual CO event.
Warning! - Constant exposures to high or low temperatures or high humidity may
reduce battery life. Use only batteries specified in marking. Use of a different battery
may have a detrimental effect on alarm operation.
For environmentally sound disposal, remove the Alarm from its mounting plate
models, open the battery door and remove the batteries) and dispose in accordance
with best practice and guidance on WEEE disposal and recycling.
Functional Gas Test
The Carbon Monoxide Alarm checks for CO gas every 4 seconds and when exposed
to the CO gas, the red light will flash (as per Table B) to confirm that it is detecting
the CO gas. Solo C6 brand canned CO testing agent may be used to verify the