Installation Manual
Installation Manual ClareOne Glass Break
Detector CLR-C1-GB-10
RF-CLR-C1-GB-10 IM V1 05042020
Batteries must be removed and re-installed to
initiate test mode after expiration. (See battery
replacement for removal of batteries).
Glass Break Tester
The glass break detector is designed to detect
the breaking of framed glass. A
Glass Break tester should be used to verify the
detector is in a proper location and can detect
breaking glass.
1. Hold the tester near the surface of the glass
and behind any closed drapes or blinds, aim
the tester at the detector and press the test
button.
2. Watch the LED on the detector, if it detects
the breaking glass sound the Red LED will
light steady and the device will transmit an
alarm.
Programming
The following steps describe the general
guidelines for programming the detector into
panel memory. Refer to the specific panel’s
documentation for complete programming
details.
1. Enter panel learn-in/enrollment mode.
2. Trip tamper switch or enter detector ID
number.
3. Enter detector information.
5. Exit program mode.
Battery Replacement
1. Remove detector cover by pressing on the
latch and pulling the cover off.
2. Insert new batteries observing polarity.
3. Replace detector cover.
Note: If a low battery alarm occurs, replace the
battery within 7 days.
Battery life depends on how often the detector
transmits signals, but is more dependent on the
temperature of the installation environment.
When the battery voltage gets low, the detector
transmits a low battery signal to the panel. The
panel then activates trouble beeps to notify the
customer that the detector battery must be
replaced. Pressing the status button identifies
the detector with the low battery.
Replace the battery immediately when this
condition occurs, using the following battery:
Panasonic CR123A 3V
Battery Disposal
The batteries used in this detector are lithium
batteries and are not reusable. Be sure to
properly dispose of used lithium batteries
according to your local hazardous waste
disposal laws.
CAUTION: Battery may explode if mistreated.
Do not recharge, disassemble or dispose of in
fire.
Specifications
Model no.
RF frequency
Compatibility
Battery type
Battery
Operating
temperature
range
Storage
temperature
range
Relative
humidity
Dimensions (L
x W x D)
CLR-C1-GB-10
433.95 MHz
Clare Control Panels 433.95
MHz
(2) 3-VDC, lithium batteries
(Model CR123A)
Varta CR123A
Panasonic CR123A
32 to 120°F (0 to 49°C)
-30 to 140°F (-34 to 60°C)
95% non-condensing
2.25 x 1.0 x 0.50 in.