Specifications
Transtig 200Pi, 250Pi, 300Pi
27
12.1 Stick Welding
PULSE
ON
PULSE
DOWN
SLOPE
CRATER
CUR.
POST-FLOW
UP
SLOPE
PULSE
FREQ.
PEAK
CUR.
(WELD)
HOT
START
PRE-FLOW
BASE
PULSE
WIDTH
INITIAL
CUR.
SPOT
TIME
Hz %(m)sec A
LIFT TIG
HF TIG
STICK
STD
SLOPE
SPOT
REPEAT
ON OFF
VRD
Refer to Manual
for correct use
Figure 5 – STICK mode
• Refer to NOTE 4 on page 26
• Refer to section 7 on page 20 for
recommendations on VRD.
• Connect work lead to negative terminal
• Connect electrode lead to positive terminal
• Switch machine on
• Set HOT START current, press control knob
• Set BASE (WELD) current, press control knob
• Connect remote control device if required
• Commence welding
12.2 HF TIG Welding
PULSE
ON
PULSE
DOWN
SLOPE
CRATER
CUR.
POST-FLOW
UP
SLOPE
PULSE
FREQ.
PEAK
CUR.
(WELD)
HOT
START
PRE-FLOW
BASE
PULSE
WIDTH
INITIAL
CUR.
SPOT
TIME
Hz %(m)sec A
LIFT TIG
HF TIG
STICK
STD
SLOPE
SPOT
REPEAT
ON OFF
VRD
Refer to Manual
for correct use
Figure 6 – HF TIG STD Mode – PULSE OFF
• Refer to NOTE 4 on page 26
• Refer to CAUTION 3 on page 26
• Connect work lead to positive terminal
• Connect TIG torch to negative terminal
• Switch machine on
• Set PRE-FLOW time, press control knob
• Set HOT START current, press control knob
• Set BASE (WELD) current, press control knob
• Set POST-FLOW time, press control knob
• Connect remote control device if required
• Commence welding
PULSE
ON
PULSE
DOWN
SLOPE
CRATER
CUR.
POST-FLOW
UP
SLOPE
PULSE
FREQ.
PEAK
CUR.
(WELD)
HOT
START
PRE-FLOW
BASE
PULSE
WIDTH
INITIAL
CUR.
SPOT
TIME
Hz %(m)sec A
LIFT TIG
HF TIG
STICK
STD
SLOPE
SPOT
REPEAT
ON OFF
VRD
Refer to Manual
for correct use
Figure 7 – HF TIG STD Mode – PULSE ON
• Refer to NOTE 4 on page 26
• Refer to CAUTION 3 on page 26
• Connect work lead to positive terminal
• Connect TIG torch to negative terminal
• Switch machine on
• Set PRE-FLOW time, press control knob
• Set HOT START current, press control knob
• Set PEAK CUR current, press control knob
• Set BASE (WELD) current, press control knob
• Set PULSE WIDTH % for PEAK CUR, press
control knob
• Set PULSE FREQ, press control knob
• Set POST-FLOW time, press control knob
• Connect remote control device if required
• Commence welding