Specifications
Transtig 200Pi, 250Pi, 300Pi
14
6. Specifications
Description (NOTE 2) Transtig 200Pi Transtig 250Pi Transtig 300Pi
Power Source Part Number 700720 700721 700722
Plant Part Number 700730 N/A N/A
Cooling Fan Cooled Fan Cooled Fan Cooled
Welder Type & Welding process Heavy Duty Inverter;
DC GTAW (TIG) &
MMAW (Stick)
Heavy Duty Inverter;
DC GTAW (TIG) &
MMAW (Stick)
Heavy Duty Inverter;
DC GTAW (TIG) &
MMAW (Stick)
Welding Power Source mass 8kg 18kg 22kg
Dimensions H260mm x W130mm
x D340mm
H360mm x W180mm
x D420mm
H420mm x W210mm
x D450mm
Designed to European Standard IEC 60974-1 IEC 60974-1 IEC 60974-1
Number of Phases Single Phase Three Phase Three Phase
Nominal Supply Voltage 240V ±10% 415V ±10% 415V ±10%
Nominal Supply Frequency 50/60Hz 50/60Hz 50/60Hz
Mains Fuse & Circuit to suit factory fitted
Lead that will achieve the following rated weld
current/weld process:
GTAW Current & Duty Cycle
MMAW Current & Duty Cycle
ª 16A
100A @ 100%
65A @ 100%
ª 17A/Phase
250A @ 40%
250A @ 40%
ª 22A/Phase
300A @ 30%
300A @ 30%
Mains Fuse & Circuit to achieve the
maximum rated weld current/weld process,
refer to section 8.4 on page 21:
GTAW Current & Duty Cycle
MMAW Current & Duty Cycle
ª 34A
µ200A @ 20%
µ140A @ 25%
ª 17A/Phase
250A @ 40%
250A @ 40%
ª 22A/Phase
300A @ 30%
300A @ 30%
Maximum TIG Current & Duty Cycle µ200A @ 20% 250A @ 40% 300A @ 30%
Maximum MMAW Current & Duty Cycle µ160A @ 19% 250A @ 40% 300A @ 30%
GTAW Welding Current @ 100% Duty Cycle 100A 160A 160A
MMAW Welding Current @ 100% Duty Cycle 70A 160A 160A
Effective Input Current for Max Welding
Current @ 100% Duty Cycle
17A 10.8A/Phase 12A/Phase
Maximum Input Current for Max Welding
Current
34A 17A/Phase 22A/Phase
Maximum Input Current for Short Circuit 34A 17A/Phase 22A/Phase
Single Phase Generator Requirement
♣ 10kVA ♣ 12.5kVA ♣ 16kVA
Flexible Supply Cable Size Factory Fitted 20A Heavy Duty 25A Heavy Duty 25A Heavy Duty
Thermal Protection Thermal Sensors Thermal Sensors Thermal Sensors
Welding Current Range 5 – 200A 5 – 250A 5 – 300A
Nominal Open Circuit Voltage (OCV) 67V 62V 62V
ª Motor start fuses or thermal circuit breakers are recommended for this application.
♣ The Generators stated kVA ratings MUST be adhered to minimise the welding Power Source’s possible
failure as a result of inadequate Mains Power at the welder’s MAXIMUM welding current and MAXIMUM
duty cycle. Warranty will be void if the welding Power Source fails as a result of being operated on
inadequate Mains Power.
µ To achieve these ratings, the 15 Amp plug (as supplied) must be replaced with a 20 Amp plug. This must be
carried out by a qualified electrical tradesperson.